1 / 7
Prusa MK4 / MK4s fix y motor holder, Option 1 or 2 — zdjęcie 1
1 / 7

Prusa MK4 / MK4s fix y motor holder, Option 1 or 2

Zamów wydruk tego modelu

Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.

Zapisane na tym urządzeniu.

Small clearance for the heat pad caused the motor to tilt when tightening the bolt.

Ocena
0 / 5
Polubienia
20
Pobrania
44
Wydruki
0
Wyświetlenia
896
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Licencja
GNU General Public License v2.0

Print Petg 

photo below printed by Prusament PCCF

0,2mm structural

3 perimeters

 

 

Option 1  - helped a lot to straighten the y-axis belt and reduce vibration.

for variant 1, only new M3nS matrices (2x) are needed if they cannot be extracted from the original model.

 

 

 

 

- adjustment of the right motor holder (0,2mm) and small design changes, other dimensions remained as the original y holder

The small clearance for the thermal pad caused the motor to deflect when the bracket was tightened.

 

 

I added 0.2 mm to the width of the bracket.

 

 

Alignment from the top of the engine, nose removed.

 

M3×18 - 3× from the original holder

 

I recommend cleaning the hole with a 3.2 mm drill, the 3* 10 mm (2ks original) screws must be screwed in by hand. Very important for option 2

do not use a drill, clean by hand in a rotating motion

 

 

100 % nut alignment and free movement of the screw by hand !!!

 

 

Option 2 - includes option 1 right mount plus new left mount.

please, if you use this option, give feedback about the results. Thanks

this variant requires skill and precise work, if you choose variant 2 it is at your own risk, it requires intervention in the frame and engine of the printer. !!!!

 

new is needed
⬢Screw M3x10 (2x) bracket to the frame
⬢M3nS mother (2x)
screw m3×50 (2×) to attach the left bracket to the engine
optional thermal paste

 

 

 

print the drilling template

attach to the frame

use a 4mm drill bit

 

 

 

again, 100% preparation of the part and fitting of the nuts is required.

 

before mounting the left motor mount, check the correct alignment of the holes, everything must fit 100% and both screws must be screwed in by hand !!!

if the new holes for the left bracket do not match, a larger drill bit, e.g. 4.6, and large-area washers must be used.

under no circumstances interfere with the original hole in the printer frame!!!

 

 

 

 

if it is 100% spliced, we can attach a new holder to the motor, here you need to remove the original 2 screws of the motor cover and replace them with m3x50, the dimensions must be observed!!!

use a sharp new screwdriver, the screws are very soft and you can damage them. I recommend pushing and pulling, they are torqued during manufacture and hold well.

 

 

 

 

for better heat transfer, I used thermal paste on the processor coolers

 

 

attach and loosely tighten the screws by hand!!

 

 

 

if you were precise when drilling and aligning, the entire holder can be freely adjusted slightly to the ceiling level before tightening

 

 

tighten all 4 screws m3*10 to the frame, everything should be easy to tighten. !! If not, arrange a remedy. Otherwise you will destroy the mothers in the holder !!

 

done


 

 

 

 

just to be sure, i did the xyz calibration, and the input shaper with the help of the prusa accelerometer

 

 

 

Tagi