Silver King 40H Milk Dispenser Valve - Part #60016-2
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
Replacement for obsolete plastic insert unit
- Ocena
- 0 / 5
- Polubienia
- 0
- Pobrania
- 5
- Wydruki
- 0
- Wyświetlenia
- 40
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Kitchen
- Licencja
- Creative Commons — Attribution — Noncommercial — Share Alike
Obsolete milk dispensing unit at my place of employment had one of the plastic valve units from the dispenser assembly break. There is a heavy weight that bolts directly to the nozzle portion, and I believe that fully tightening the bolts cause the original part to crack. My design has depressions that allow the tips of the bolts to snug up nicely without applying too much pressure, and the design is also modular so you only need to reprint the nozzle portion if there is breakage without having to reprint the entire assembly.
I understand the likelihood that anyone else will ever need this part for this obsolete unit in the remainder of humanity is slim, and even more slim that they would find their way to this post and have a 3D printer available to them, but I would love if someone else can benefit off of the work I put into this. As of the time of posting, I only see this part available in two places: eBay has a seller listing one for $99 +$16 shipping, and another place has one for $514.13. This unit cost me $3.16 to print, and I hope I can save someone else some money.
This was printed using PETG, as PLA would be more susceptible to creep, but this would potentially be better printed in a PC or nylon if you have the capability (or want to send to a print service that can). I increased the perimeter walls, as well as the top and bottom later count, to 10 so the unit is essentially solid in all of the areas that matter, and printed the nozzle at a 45 degree angle to (hopefully) reduce the chance of delamination. That being said, I tested the unit pretty heavily at only 2 walls and the nozzle printed vertically (layer lines running horizontally), and it seemed to hold up well to dropping the weighted handle from full height with no tube to cushion the impact, and even purposefully throwing the weighted handle downwards. Not that I recommend relying on this unit long term with only 2 walls, just that I tried to test some worst-case scenarios.
One thing I would warn is that, when printing the nozzle at a 45-degree angle, the fit was a bit more snug than when printed at the same orientation as the main body, which allowed a firm, yet removable, press fit. This might mean that you have to sand a bit to get a nice, press fit between the nozzle and the body, or in my case, I used a dead-blow hammer to set the nozzle in place.