Palo Alto PA-445 1U Rack Mount with PSU Bay (true 1U, no supports)

Zamów wydruk tego modelu

Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.

Zapisane na tym urządzeniu.

True 1U rack mount for the Palo Alto Networks PA-445 firewall with an integrated bay for the external 150 W power brick.

Ocena
0 / 5
Polubienia
1
Pobrania
5
Wydruki
0
Wyświetlenia
26
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Kategoria
Computers
Licencja
Creative Commons — Attribution — Noncommercial

What it is

A two-bracket 1U mount for the PA-445 desktop firewall. 1U pitch leaves 2.25 mm of headroom around the 42.2 mm chassis, so there is no room for a full-width printed tray — instead the unit's own aluminium chassis spans between two end brackets, exactly as the commercial steel kits do. The right bracket integrates a closed-front, top-loading bay for the external PSU brick with zip-tie slots and a rear cable notch sized to pass leads with the plugs/ferrite never threading through anything.

Parts

  • bracket_l — left bracket: rack ear, closed-cell twin-wall structure, 2 mm lip shelf under the unit's left end

  • bracket_r — right bracket: ear, PSU bay (interior 84 × 202 mm, walls 43.6 mm), lip shelf, cable notch. bracket_r_logo variant has a 62 × 34 × 1.6 mm recess for the badge

  • rear_bar — rectangular tie behind the unit, 1× M3×20 + nut per end into printed nut traps. 332 mm: print diagonally on a 256 bed

  • ear_doubler (print 2) — flat plate sandwiched under the rack bolts. Its layers run across the ear's layer lines and stop bolt-torque splitting the ear. Strongly recommended for CF filaments

  • badge / badge_field / badge_blue / badge_gold (optional) — flat 1.6 mm multi-colour logo plate for the recess, supplied as separate coplanar bodies for per-part filament assignment

Print settings

  • Orientation: all parts flat as modelled. No supports anywhere.

  • 0.4 nozzle, 0.2 mm layers, 6 walls, 40 % infill

  • Material: ABS or ABS-CF recommended for the brackets/bar (rack temperatures; PLA creeps under sustained load — use it only for fit checks). PETG works. Print ear doublers in the same material.

  • Rear bar prints diagonally (~40°) on 256 mm beds.

Hardware (BOM)

  • 4× M6 cage nut + bolt sets (or Rackstuds), penny washers recommended

  • 2× M3×20 + 2× M3 nuts (rear bar)

  • Zip-ties or 20 mm Velcro for the PSU brick

  • Optional: CA glue for the badge

Assembly

  1. Rack both brackets loosely with the ear doublers under the bolt heads. Snug only — it is plastic, not a switch bracket.

  2. Drop the PA-445 in from above; it sits on the lip shelves, retained forward by the 4 mm face overlaps.

  3. Fit the rear bar: nut into each top slot, M3×20 through each flank wall. Square up, torque the rack bolts (gently).

  4. PSU brick into the bay from above, mains end rearward. DC lead routes back over the brick lid (9 mm headroom), ferrite sits in the rear void, both leads exit the rear notch. DC lead runs forward in the rack side space to the front power inlet.

  5. Zip-tie the brick. Done.

Notes

  • Designed parametrically in OpenSCAD; source included. Bay width, clearances and all dimensions are variables.

  • The PA-445 chassis is 330.2 × 225.6 × 42.2 mm (PAN hardware reference). This mount fits the PA-445 specifically — the PA-440/450/ 460 are a narrower chassis and will NOT fit.

  • Unit top sits 0.6 mm proud of the 43.6 mm face — inside the 44.45 mm 1U pitch, standard practice.