A retrofit BMS board repair for a 1.5AH battery that had a locked up original BMS board, but the cells were fine.

Ocena
0 / 5
Polubienia
0
Pobrania
0
Wydruki
0
Wyświetlenia
44
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Kategoria
Electronics
Licencja
Creative Commons — Attribution

Care should be taken working or modifying lithium cells. Ryobi batteries sometimes will refuse to work or charge and returns an error code light. A code has been rewritten on the BMS board that locks out the board from working. A hard reset will not clear the code, and the battery will never work again. I have used a generic 5 cell BMS board with a DC connector and 24V power supply to make the battery usable again. 

Prep: First step is to check cells and see if they are good and make sure the cells voltage range are within 0.5V of each other. Cut or desolder the wires on the upright stem from main board. It will be reused. Remove center conductor wire. Of the two remaining wires, positive and negative, the shorter one will need to be replaced with a longer one. Take out the three screws and desolder main board from the battery pack and remove. You will be left with the bare battery pack and stem. 

Assembly: Use the printed plug for the hole in the top cover. Press in place and hot glue in. On the curved side of the top cover measure around halfway down from the inside for the 5/16" {8mm} hole. Put the DC connector in and tighten nut. Mount the replacement printed board with the three screws. The other three holes are for the alignment pegs. Apply solder to the eight points on the BMS board. Hot glue the BMS board to the PLA plate, I used 20AWG wire for the charging point between cells and 16AWG for positive and negative to the battery and DC charge port. Note: (After I assembled mine, I used a 24V 1.5A DC charger and monitored the current. It only charged at 170 to 180ma. At that point you could use the 20AWG wire for the positive and negative battery contacts and DC charging port). Use the diagram and pictures for guides. The DC center contact is positive. To find negative contact on the three-lead connector insert a plug into it and measure resistance from case to the contacts to find the right one or a power supply and measure for voltage. Snap in the upright stem and solder the wires to the board. It is best to try not to cross wires because the top, when assembled, will press down on the wires.

Testing: I tested the battery with a light on until it went out. The BMS board did its job and shut down the battery at a lower limit. Unfortunately, it took many hours to charge the battery at the 170 to 180ma rate, but it did shut off charging at a high limit. I put the battery in a Ryobi charger, and it did not see the battery due to the center post and the base contact not being available. Though not tested I would not advise using the battery in a high current application. This retrofit worked on the battery pictured and may work on others.

The BMS board and DC connector purchased from Amazon. Basic PLA and settings