1 / 1
Slip in/out bowden tube holder clip to facilitate  QIDI X-Max 3  'Filament release' function — zdjęcie 1

Slip in/out bowden tube holder clip to facilitate QIDI X-Max 3 'Filament release' function

Zamów wydruk tego modelu

Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.

Zapisane na tym urządzeniu.

Simple retainer for the top of extruder that holds the bowden tube without gripping it.

Ocena
0 / 5
Polubienia
13
Pobrania
146
Wydruki
0
Wyświetlenia
1540
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Licencja
Creative Commons — Public Domain

Alternative  methods to the one presented here. 

  • Simon Prevett  at the QIDI Tech 3d Printer Owner forum described:  If you cut a very small piece of ptfe tube and insert it into the head and leave it their then the next section of tube just butts up too it, it won’t go anywhere as it’s being pulled forward. And when it’s time to cut, just pull on the main tube and you expose the filament right at the head. Hope this makes sense. I just cut my original tube at the head, about 5mm up from the black collar.  Sounds like effective solution. I would just suggest additionally making the slicer End G-Code change listed below to also center the print head at the end print. 
     
  • Closer to a production workaround which provides a gap to cut the filament without any ptfe tube handling.  https://www.printables.com/model/818575-easycut
     
  • And then the one presented below, similar to first listed, but allows re-connection immediately after cutting the filament, so when filament is reloaded you just load it .

Simple clip that replaces the tubing clip at the top of the extruder to make it easier to remove the bowden tube when cutting the filament at before using the QIDI ‘Release Filament’ function.  The original clip can be removed by removing the hot end front cover, then push up on the clip from the access hole now exposed. Replace the cover and push this slip clip into the hole.

Printing: 
Place upside down on slicer bed so the cone is pointing down. No supports are necessary, I used a brim. I printed in PETG so chamber temp is not a problem. 

The QIDI recommendations their  'Replacement Filter' procedure which avoids the retraction of filament backward through the hot end to avoid clogs. Involves cutting the filament just before the extruder, heating the hot end and extruding the filament from the extruder. It's not a great procedure to impose on the customer, but avoids the outcome of a clogged hot end.  

To make the ‘Release Filament’ procedure handier, I suggest adding the following gcode to the print End G-Code settings in the slicer or Klipper.  It moves the print head to the center of bed at the end of the print for easier access, avoids manual movement. 

     G90     ; switch to absolute positioning
     G0  X150 Y150  F3600 ; Was X0 Y0,  X150 Y150 moves print bed to center of bed.

Also I am loading a sliding Lid top cover model to printables for the X max 3. Allows  the top cover to be slid open to vent or access the the print head without completely removing the lid. Search Printables for QIDI X-max 3 Lid Slider

Also I used additional bowden tube clips to hold the bowden tubing to the chain cable. Search printables for K1 Max Bowden Tube Clips .  

Feedback Good or Bad will help me and the next guy who may be interested in trying this model.