1 / 5
FILAMENT DRY BOX – MODULAR SYSTEM WITH PTC — image 1
1 / 5

FILAMENT DRY BOX – MODULAR SYSTEM WITH PTC

Order a print of this model

We calculate the final price from your selected file. You review and accept it before payment.

Saved on this device.

Modular system designed for the continuous storage and drying of 3D filaments

Rating
0 / 5
Likes
236
Downloads
156
Makes
0
Views
8,157
Reviews
0

Updated at source:

Model information

Category
Accessories
License
Standard Digital File License

A modular system designed for the continuous storage and drying of 3D filaments, utilizing:

  • hot air circulation

  • PTC heating element

  • 120mm industrial-grade metal fan

  • thermal insulation

  • smart control via Tuya / Smart Life

Ideal for:

  • PLA

  • PETG

  • ABS

  • TPU

  • Nylon

  • hygroscopic filaments

The system was designed for:

  • low power consumption

  • high efficiency

  • stable temperature

  • low humidity

  • continuous operation

KEY FEATURES

✅ Vertical hot air circulation

✅ Closed system with internal recirculation

✅ Low energy consumption

✅ Smart control via Tuya app

✅ Modular and expandable

✅ Compatible with 120x120x38mm industrial fans

✅ Compatible with 100W PTC (98x32x26mm)

✅ Easy to 3D print

✅ Excellent thermal stability

✅ Professional-style DIY dry cabinet

OPERATION

The industrial fan pushes air through the PTC heating element. Hot air rises vertically:

  • passing through the heating elements

  • reducing humidity

  • stabilizing the temperature

The system utilizes:

  • internal recirculation

  • aluminized thermal insulation

  • auxiliary shelf

Airflow:

  • rises through the center

  • spreads at the top

  • descends along the sides

  • returns to the system

RECOMMENDED CONFIGURATION

Temperature:

  • 45°C ~ 50°C

Humidity:

  • 10% ~ 20%

Control:

  • Tuya sensor

  • Automation via Smart Life / Tuya

PRODUCTS USED

Tuya WiFi Mini Switch

01 unit -

Mercado Livre

Tuya WiFi Mini Switch

AliExpress:

Tuya WiFi Mini Switch

120mm Industrial Metal Fan (110/220V)

02 units -

Mercado Livre

120mm Industrial Metal Fan

AliExpress

120mm Industrial Metal Fan

Note:

  • metal model required

  • 110/220V required

  • Recommended size: 120x120x38mm

Aluminized Thermal Insulation

03 units -

Mercado Livre

Aluminized Thermal Insulation

AliExpress:

Aluminized Thermal Insulation

Note:

  • Quantity may vary based on:

  • cabinet size

  • number of compartments

  • internal area used

Tuya Temperature and Humidity Sensor

01 unit -

Mercado Livre:

Tuya Temperature and Humidity Sensor

AliExpress

Tuya Temperature and Humidity Sensor

Double-sided Tape

01 unit -

Mercado Livre

Double-sided Tape 12mm x 20 meters

AliExpress

Double-sided Tape 12mm x 20 meters

PTC Heating Element 100W 98x32x26mm

02 units

PTC Heating Element 100W 98x32x26mm

SETTINGS PRINTING

Material: Recommended

  • ABS

  • ASA

Not recommended:

  • PLA

Suggested settings

Layer height:

  • 0.20 mm

Infill:

  • 30% ~ 40%

Perimeters:

  • 4

Supports:

  • Not required

Brim:

  • Inner and Outer - 15mm

SAFETY

  • ⚠ Never use PLA near the PTC

  • ⚠ Never let filament touch the heater directly

  • ⚠ Use only industrial-grade metal fans

  • ⚠ Use the system in a dry, indoor environment

  • ⚠ Inspection recommended during initial tests

  • ⚠ Screw locations are offset inward, requiring a nut or a simple press-fit; they do not screw directly into the structure.

FILES

The project includes:

  • Modular PTC + 120mm fan mount

  • Vertical circulation system

  • Assembly optimized for dry cabinets

Compatible with:

  • 120x120x38mm fan

  • 98x32x26mm PTC

RECOMMENDATIONS

For best results:

  • Mount on the door

  • Maintain slight passive airflow at the bottom

  • Use a desiccant (calcium chloride)

  • Keep the sensor at the average height of the filaments

PROJECT OBJECTIVE

Create a solution that is:

  • Efficient

  • Low-cost

  • Modular

  • Quiet

  • Professional-grade

  • Easily reproducible

For the storage and continuous drying of 3D printing filaments.

------------------------------------------------------------------------------------------------------------------------------

DRY BOX SYSTEM INSTALLATION

1. CABINET PREPARATION

Choose a cabinet that is:

  • enclosed

  • sturdy

  • preferably MDF/wood

  • spacious enough for internal air circulation

The system is designed to operate in:

  • a virtually enclosed environment

  • internal hot air recirculation

  • low external air exchange

2. THERMAL INSULATION INSTALLATION

Before installing the thermal insulation:

✅ Thoroughly clean the cabinet's interior surfaces.

Recommended:

  • dry cloth

  • isopropyl alcohol (optional)

IMPORTANT

Before adhering the thermal insulation:

⚠ Apply double-sided tape to ALL interior walls of the cabinet.

Double-sided tape:

  • improves adhesion

  • prevents peeling due to heat

  • keeps insulation secure

  • improves the finish

RECOMMENDED INSULATION AREAS

Apply insulation to:

  • interior sides

  • back panel

  • doors

  • floor

  • interior ceiling

  • dividers/shelves

Recommended:

  • keep the aluminized side facing inward

3. HOLES BETWEEN SHELVES

VERY IMPORTANT

The system relies on the vertical circulation of hot air.

Therefore:

⚠ There must be holes between:

  • lower compartment (PTC + Fan)

  • upper compartment (filaments)

HOLE RECOMMENDATIONS

You can use:

✅ Circular holes

OR

✅ Horizontal slots

Calculated quantity

Suggestion:

  • 8 to 12 holes

  • 40mm to 50mm in size

Distribution:

  • preferably in the central area

FUNCTION OF THE HOLES

The holes allow for:

  • rising hot air

  • circulation

  • uniform temperature

  • efficient filament drying

Without the holes:

  • hot air gets trapped at the bottom

  • drastically reducing system efficiency

4. INSTALLING PTC MODULES + FANS

Position the modules:

  • at the bottom of the enclosure

  • aligned with the upper holes

  • with side clearance for circulation

IMPORTANT

The fans must:

  • ✅ Blow air through the PTC

  • ✅ Direct the airflow upwards

The system must NOT:

  • ❌ continuously draw in outside air

  • ❌ act as an exhaust fan

5. TEMPERATURE AND HUMIDITY SENSOR

The sensor should be placed:

  • in the filament area

  • at the average height of the spools

  • away from the direct path of the hot airflow

6. DESICCANT / CALCIUM CHLORIDE

Recommended:

  • position at the bottom

  • near the airflow

  • away from direct contact with the PTC

7. SEALING

For best efficiency:

Recommended:

  • EVA seals on the doors

  • minimize outside air intake

The system works best:

  • semi-sealed

  • with internal recirculation

8. FIRST TEST

During initial tests:

✅ Monitor:

  • temperature

  • humidity

  • airflow

⚠ Never let filaments come into direct contact with the PTC.