1 / 8
12V LiFePO4 Inverter Pre-Charge Circuit Enclosure — image 1
1 / 8

12V LiFePO4 Inverter Pre-Charge Circuit Enclosure

Order a print of this model

We calculate the final price from your selected file. You review and accept it before payment.

Saved on this device.

Pre-Charge circuit box.. Simple circuit required to ease high-wattage, low-impedance devices to slow-draw to avoid trips

Rating
0 / 5
Likes
3
Downloads
4
Makes
0
Views
128
Reviews
0

Updated at source:

Model information

Category
Electronics
License
Creative Commons — Attribution

This is a small enclosure I designed for a simple manual pre-charge circuit used with a Victron MultiPlus 12V / 3000VA inverter/charger and a LiFePO4 battery bank.

Large inverters can contain a substantial bank of input capacitors. When an inverter is connected to a low-impedance LiFePO4 battery bank, those discharged capacitors can momentarily look almost like a short circuit. The resulting inrush current can create a large spark, stress disconnect switches, or—in my case—trip the internal BMS protection in one or more batteries.

Rather than allowing the battery BMS to deal with that surge, this circuit provides a small, current-limited path that charges the inverter capacitors before the main DC disconnect is closed.

How it works

The pre-charge branch is connected across the two sides of the inverter's main positive DC disconnect.

When the rocker switch is turned on, battery current reaches the inverter through a 10Ω / 50W resistor, limiting initial current to roughly 1–1.5 amps on a 12V system.

As the inverter capacitors charge, the voltage difference across the open disconnect falls toward zero.

Once the capacitors are charged, the main DC disconnect can be closed with very little remaining inrush current. The pre-charge switch is then turned back off.

For my Victron MultiPlus, approximately 8–10 seconds of pre-charge time provides plenty of margin.

Easy-to-source components

I intentionally designed this around inexpensive, readily available parts that can be purchased from Amazon rather than specialized electronics suppliers.

The enclosure is designed around the following components:

10Ω 50W aluminum power resistor
uxcell 50W 10 Ohm aluminum-housed wirewound resistor
Amazon ASIN: B07H3253TR

Pre-charge rocker switch
DaierTek miniature SPST ON/OFF rocker switch
Amazon ASIN: B07S2QJKTX

Digital voltage indicator
bayite 0–30V three-wire mini digital voltmeter
Amazon ASIN: B00YALV0NG

3A inline fuse holder
Gaoekoius 18AWG inline fuse holder with 3A fuse
Amazon ASIN: B0DC3LVV75

Isolated meter power
4xAA battery holder
Amazon ASIN: B0DZWK2TNY

The separate AA battery supply allows the three-wire voltmeter to remain electrically isolated from the main battery system. This lets the meter directly measure the voltage difference across the open disconnect—from nearly full battery voltage at the beginning of pre-charge down toward 0V as the inverter capacitors charge.

Typical operating sequence

  1. Leave the inverter itself switched OFF.

  2. Open the main inverter DC disconnect.

  3. Turn the PRE-CHARGE rocker switch ON.

  4. Watch the voltage across the disconnect fall.

  5. Wait approximately 8–10 seconds, or until the remaining difference is approximately 0.5V or less.

  6. Close the main DC disconnect.

  7. Turn the PRE-CHARGE switch OFF.

  8. Turn the inverter on normally.

Why I built this

My battery bank consists of multiple 12V LiFePO4 batteries in parallel. The Victron MultiPlus worked normally once powered, but connecting its discharged capacitor bank could produce enough instantaneous current to trigger battery BMS protection.

Nothing was actually wrong with the inverter—the issue is simply a consequence of combining:

  • a large inverter capacitor bank,

  • very heavy low-resistance battery cabling,

  • and LiFePO4 batteries with fast electronic over-current protection.

A pre-charge resistor gives those capacitors a few seconds to charge gently instead of asking the BMS to absorb the entire connection event.

This is essentially a simple manual version of the pre-charge systems used in larger professionally managed battery installations.

Printing

The model consists of:

  • Main pre-charge circuit enclosure

  • Removable enclosure cover

The enclosure was designed around the components listed above, so substitute parts may require modification depending on their dimensions.

As always with high-current DC systems, use appropriately rated wiring, fusing, disconnects, and terminals. The small pre-charge circuit does not carry the normal inverter operating current—the main DC cable and disconnect continue to handle that load.

Tags