Azimuth/VTA calibration gauge
We calculate the final price from your selected file. You review and accept it before payment.
Saved on this device.
Attach to the headshell and adjust azimuth and VTA by ensuring no light is visible between the edges and record surface.
- Rating
- 0 / 5
- Likes
- 4
- Downloads
- 5
- Makes
- 0
- Views
- 105
- Reviews
- 0
Updated at source:
Model information
- Source
- Printables
- Category
- Audio
- License
- Creative Commons — Attribution — Noncommercial — Share Alike
Attach to the headshell and use it to adjust azimuth and VTA by ensuring no light is visible between the edges and an average height record. For azimuth focus on the front edge, and for VTA adjust so both edges are on the record surface
Check out my website for other audio related tools: www.s16n.com
For VTA, this has 17.1mm height, which is calculated loaded height at 2g using the published for azimuth it will work for any cartridge. For azimuth it will work for any cartridge.
For VTA stylus deflection should be calculated or measured. I used the published static compliance, but note that is nominal, 2g VTF is nominal, and this is 3D printed, so this has nominal accuracy for VTA.
Is it better than a mirror for setting azimuth? Yes definitely, with the caveat that it cannot account for zenith angle - though to do that properly you really need pro tools and experience. If your stylus is straight it's fine.
Print with precise z-height and ironing.
It can of course be modified to other cartridges by calculating the required height. If static compliance is not published, 0.3mm deflection is going to get you close. You can also measure it!
Math for required 17.1mm height
Static compliance is 20×10−620 x 10^{-6}20×10−6 cm/dyne.
2.0 g ≈ 1960 dynes.
Deflection = 20×10−6×1960=0.039220 x 10^{-6} x 1960 = 0.039220×10−6×1960=0.0392 cm ≈ 0.39 mm.
For the AT-VM740xML, catalog body height minus ~0.4 mm is the calculated loaded height at standard VTF.
17.5 mm (catalog body height).
Loaded height at 2.0 g ≈ 17.5 − 0.39 ≈ 17.1 mm.