Ai3M (Anycubic i3 Mega) Bed Handle (Remix) with ADXL345 Accelerometer Mount for Klipper
We calculate the final price from your selected file. You review and accept it before payment.
Saved on this device.
ADXL345 Accelerometer Mount for Klipper, That attached to bed of Ai3M. Part of a pair of matching pieces.
- Rating
- 0 / 5
- Likes
- 13
- Downloads
- 93
- Makes
- 0
- Views
- 1,002
- Reviews
- 0
Updated at source:
Model information
- Source
- Printables
- Category
- Anycubic Parts & Upgrades
- License
- Creative Commons — Attribution
COMPANION PART:
https://www.printables.com/model/342844-ai3m-anycubic-i3-mega-biqu-h2-adxl345-acceleromete
https://www.thingiverse.com/thing:5722491 (backup in case its ever not available here)
NOTE: I may modify the design to rotate it to match the orientation of the toolhead mounted sensor. This would be so it sits oriented in such a way as to line up the printer's axis with that of the sensor. Not necessary, but I like consistency. Point is, if you want that, check back and you may find an updated version.
First: yeah my print was wonky - I ran it faster than the filament could cool. Works just the same. Yours should look better.
This is useful only if you are running Klipper, and have an ADXL345 Accelerometer (or a pair of them, one for the toolhead and one for the bed). I don't know if this will fit any others.
I made the part I jammed on to this bed handle a while ago, so I am going off memory, but I'm fairly sure it is exactly a 15mm spacing between hole-centers, so you could check your accelerometer and figure out if it would fit.
The screw holes are for 6mm long M3 screws, and the hole diameter as modeled is 3.0mm if I remember right, to ensure a positive grab. I left skipped inserts because they would add weight, but it does need to hold secure enough that the accelerometer is firmly mounted (all vibration from the printer needs to transfer to the accelerometer to be measured).
My printer is fairly well dialed in, so my tolerances were on point. You may need to adjust or drill out the screw holes if your printer is over-extruding on internal perimeters.
Please ignore the ugly blue-tape. It is bad practice but TPU on glass had me worried.
There is a companion piece specifically for the BIQU H2 direct-drive toolhead. Unless you are running this same combo, you will need to figure out your own way to mount the sensor (accelerometer) there.
Included is the FreeCAD file.
If you remix this or put it in to practice, please reference back to the prior creator(s). They made this easy.
Original Design:
https://www.thingiverse.com/thing:3578977
Why would someone want to strap an accelerometer to their printbed:
https://damlobster.github.io/klipper/Measuring_Resonances.html