1 / 3
SR550 Server 60x25mm Fan Adapter for Silent Cooling — image 1
1 / 3

SR550 Server 60x25mm Fan Adapter for Silent Cooling

Order a print of this model

We calculate the final price from your selected file. You review and accept it before payment.

Saved on this device.

Enables seamless OEM fan replacement in SR550 servers for quieter operation without chassis modification.

Rating
0 / 5
Likes
2
Downloads
23
Makes
0
Views
288
Reviews
0

Updated at source:

Model information

Category
Computers
License
Creative Commons — Attribution

This adapter enables the installation of 60mm x 25mm fans into Lenovo SR550 servers, reducing noise without affecting cooling. It uses two 30mm M4 screws for mounting at the bottom, with an option for a zip tie at the top for extra security. Designed for easy printing and installation, the model comes pre-oriented to print with critical features like the notch directly on the build plate, eliminating the need for support structures. This ensures a precise fit and optimal functionality with standard 60mm x 25mm fans, making it a straightforward solution for upgrading server cooling systems.

Key Points:

  • Material & Settings: Printed in PETG with a 0.4mm nozzle and 0.2mm layer height, optimized for a line width of 0.42mm, balancing durability and detail.
  • Design Evolution: Initial designs used four screw mounts, but were revised to avoid air duct interference, now featuring bottom screws and a top zip tie option for versatility and ease of installation.

This adapter represents a practical, community-driven approach to server cooling, focusing on simplicity and effectiveness. Feedback and shared experiences are encouraged to refine this solution further.

Fan Adapter and Wiring Details

To integrate new 60mm x 25mm fans into the Lenovo SR550 server, a custom adapter is created using the fan's original wiring configuration: black for ground, yellow for the RPM signal, blue for PWM control, and red for 12V power. A 4-pin 2.54mm header is prepared by crimping stripped wires from a fan splitter, included with the fans, facilitating a direct connection between the server's motherboard and the new fans. This setup maintains fan speed monitoring and control functionalities.

The current configuration exploits a specific BIOS feature that runs the fans at 100% capacity when it detects a fan missing. This setup uses only two headers on the motherboard, yet the fans operate at full speed, significantly quieter than the original equipment manufacturer (OEM) fans at 30% speed. This approach has proven effective, with server temperatures stable at approximately 22°C idle and 44°C under full load conditions, using an 85W TDP CPU. It's important to monitor temperatures post-modification to ensure cooling efficiency remains uncompromised. I encourage others to test their systems to find the optimal balance between noise reduction and cooling performance.

Photographs detailing the adapter creation process and the final installation will be shared to assist others interested in this modification. This documentation aims to provide a clear, step-by-step guide to achieving a quieter server setup without sacrificing thermal management.