1 / 3
FLSun Q5 LGX Lite V2 Mount + ADXL345 mount. NEW V2! — zdjęcie 1
1 / 3

FLSun Q5 LGX Lite V2 Mount + ADXL345 mount. NEW V2!

Zamów wydruk tego modelu

Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.

Zapisane na tym urządzeniu.

A new hotend cage that facilitates mounting a Bondtech LGX Lite V2 to the FLSun Q5, and adds several enhancements

Ocena
0 / 5
Polubienia
6
Pobrania
12
Wydruki
1
Wyświetlenia
200
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Licencja
Creative Commons — Attribution — Share Alike

EDIT 12/23/24: I have created 2 new versions, one with an integrated ADXL345 mount, and one with FLSUN branding on the side to give some life to the otherwise blank right side. Tolerances have also been adjusted. I've provided several variations, both with and without branding and the mounts, and I have updated the cad files with the changes. I am only including branded cad files as its easy to just remove the letters in an editor.

EDIT 12/24/24: I've realized that when using a 17mm Moon's motor, the motor makes contact with 2 of the effector arms when using the full build volume. I am working on a permanent solution which possibly includes mounting the extruder at an angle or raising the extruder to dodge the arms. For now, a temporary fix is to reduce the radius of the bed in either firmware or slicer. Most people don't use 100% of the bed, so it shouldn't be a huge issue. The available bed space depends on the motor used, and with a 17mm motor I have my bed set to 90mm radius.

First off, I would like to give a huge thanks to @MarcusBuschb_1268936 for the models of both the effector and the heatsink - they were extremely useful for the design process of this model, and without them, my design would not exist.

This is a replacement hotend cage that allows for mounting a Bondtech LGX Lite V2 onto the FLSun Q5, but also makes several improvements to the hotend cage itself.

Before we get to the good stuff, here's the print parameters:
Walls/infill %/infill type are not important factors - I used 3 walls + 15% cubic and it turned out great. Does not require supports if printed upside-down!

With that out of the way… Here are the Pros of this design (in no particular order):

  • Easy wire management with integrated wire run and zip-tie point
  • Direct compatibility with TheyCallMeStrat's swappable duct system without the need for a fan spacer (aka only needs the latch part)
  • Internal funnel design that channels airflow into the heatsink, designed with Noctua fans in mind
  • Lighter than the stock cage, before you add the LGX at least :P
  • (Optional) ability to permanently mount an ADXL345, or any accelerometer with 15mm hole spacing to the toolhead. 

and the Cons:

  • Not compatible with the stock part cooling duct - Not enough space to fit it. Use Strat's duct!!
  • Requires additional hardware - see below

Still with me? Good! For this part, you will need:

  • 4x voron-style m3 heat set inserts (6 if using new integrated ADXL mount)
  • 4x m3x8mm bolts to mount the LGX (Cap must be <3mm tall, not countersunk!)
  • 2x m2x5mm-8mm plastic threading screws for the part cooling fan (the stock screws were not tested but might work fine)
  • 1x 2.5mm wide nylon zip tie
  • roughly 28-30mm of PTFE tubing. Length will vary depending on what hotend is installed. the stock hotend needs about double this 
  • Stock screws for the fan and for mounting the cage to the effector
  • 2x m3x6 screws + m3 washers for mounting the accelerometer

I will not be doing an install guide because I think most of this is self-explanatory and not complicated, however, to save from a few headaches, here are some things to keep in mind:

  • The LGX must be installed FIRST, before anything else! If you install anything else first, the LGX mounting screws become INACCESSIBLE!!
  • The heat set inserts are for the hotend fan, effector mounting holes, and optional ADXL mount. There are no heat inserts for the part cooling fan or LGX so don't worry about em
  • Do not overtighten the part cooling fan screws. If you strip them, you will need to reprint the cage
  • Choose a heat resistant material like PETG or ABS - I am NOT responsible for melting parts, burning houses, or dead printers because you thought “PLA is fine”. It is not!
  • Don't forget about the PTFE aligner! It screws into the top of the heatsink with a 4mm hex key. This is to help keep the PTFE tube in place when putting it all together

I think that covers everything. Please don't hesitate to reach out with questions if you have any.
As always, I've included .step files so feel free to make your own modifications as you see fit. Happy printing!

Tagi