DO NOT USE: SV08 MicroProbe mount
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
MicroProbe mount for Sovol SV08
- Ocena
- 0 / 5
- Polubienia
- 2
- Pobrania
- 11
- Wydruki
- 0
- Wyświetlenia
- 397
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Other Printer Parts & Upgrades
- Licencja
- Creative Commons — Attribution — Noncommercial
Update: Do not use this model. It is to close to the hot end and even ASA started to melt after a few prints. I'm using the model made by @TeknikFriK now. It's the better design.
I was disappointed by the performance of the original probe on the SV08. Too much deviation for any serious quality results. Different build plate - new calibration neccessary. No thanks. With an Eddy it would be the same as it reacts to the metal plate and not to the top surface
I found Johns model but after fixing it just for printing I found it a little bit to flexible for my liking. So I added a reinforcement strip in the slicer and i also removed a little bit of unneccesary material but sadly i can't export it with the removed parts straight from orca or prusa slicer. You'll find that in the orca-slicer project.
I also reduced the size of the mounting holes for the probe. There wasn't enough material around for the M2.5 inserts i have. There is plenty of thread length in that model. So no threaded inserts. yay. For installation reqirements and offsets see the descriptions of John's model.
The information about wiring can be found here
Printed in Qidi ASA green. The Model isn't perfect. It touches the silicone sock on my stock hotend. It won't last forever but it does the job until i figure something out.
I'm running mainline Klipper on my printer. See the Repo on Github for details if you want to convert your SV08
Please do not use the automated z offset calibration. The MicroProbe triggers the pressure sensor which triggers the calculation of a way to big z offset. Ruined my stock bed that way today for good. Use PROBE_CALIBRATE_BASE and a sheet of paper. On my Printer i calibrated the offset manually and ended up with approx. 0.4mm. The automated process got 1.3mm. so you will crash your nozzle into the bed and scratch it badly if you use it
In my config I moved the bed mesh section to the probe file. John's X and Y offsets were spot on. Please pay attention some stuff is most likely already in your printer.cfg
## --- BIQU Microprobe Klipper configuration ---
[gcode_macro PROBE_DOWN]
gcode:
SET_PIN PIN=probe_enable VALUE=1[gcode_macro PROBE_UP]
gcode:
SET_PIN PIN=probe_enable VALUE=0
[output_pin probe_enable]
pin: extra_mcu:PB7 # Set to the control pin on your board
value: 0
[probe]
pin: !extra_mcu:PB6 # NOTE FOR V2 users: Set this to ^!PC14 to set the low level trigger
deactivate_on_each_sample: False
x_offset: -18.9
y_offset: 6.2
#z_offset: 1 # Will be overridden when you do a PROBE_CALIBRATE_BASE
samples: 3
sample_retract_dist: 10.0
speed: 5.0
samples_tolerance: 0.01
samples_tolerance_retries: 3
activate_gcode:
PROBE_DOWN
G4 P500
deactivate_gcode:
PROBE_UP
[z_offset_calibration]
center_xy_position:193.9,165
endstop_xy_position:289,361
z_hop: 10
z_hop_speed: 15
[safe_z_home]
home_xy_position: 193.9, 168.8
speed: 50.0
z_hop: 10
z_hop_speed: 25.0
[quad_gantry_level]
gantry_corners:
-60,-10
410,420
points:
36,10
36,320
346,320
346,10
speed: 350 #400
horizontal_move_z: 10
retry_tolerance: 0.02 #0.05
retries: 5
max_adjust: 17 #30
[bed_mesh]
speed: 350
split_delta_z: 0.0125
horizontal_move_z: 5
mesh_min: 10,10
mesh_max: 330,340
probe_count: 9,9
algorithm: bicubic
bicubic_tension: 0.4
mesh_pps:3,3
adaptive_margin: 5
fade_start: 0
fade_end: 10
fade_target: 0