Whirlpool PACF212HP intake adapter & exhaust brackets (parametric, PETG)
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
Whirlpool PACF212HP Ø150 mm AC ducting: parametric intake adapter + exhaust brackets. FreeCAD source, PETG.
- Ocena
- 0 / 5
- Polubienia
- 1
- Pobrania
- 18
- Wydruki
- 0
- Wyświetlenia
- 98
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Other House Equipment
- Licencja
- Creative Commons — Attribution — Noncommercial — Share Alike
Whirlpool PACF212HP intake adapter & exhaust brackets (parametric, PETG)
Parametric FreeCAD adapter set for the Whirlpool PACF212HP W portable air conditioner. It ducts both the intake and the exhaust side to standard Ø150 mm aluminium flex hose, so the unit can draw and expel air through the hose instead of the room.
Fully parametric — change one value in the spreadsheet to fit another hose diameter or a different unit.
Important: the AC grille area NOT covered by the intake adapter must be sealed/blocked, otherwise the unit draws room air instead of the ducted outside air. Simplest option: duck tape (not pretty; a cleaner solution is TBD).
What's in the set
Intake adapter — rectangular-to-round transition that mounts onto the AC intake grille, with a Ø150 mm hose neck and a built-in access tunnel for the AC's original retaining screw.
Exhaust brackets (2 pcs) — hold the original Whirlpool stock exhaust part (stadium-shaped opening outside, round inside) against a plywood window panel.
Compatible model
Whirlpool PACF212HP W portable air conditioner
Hose: aluminium flex Ø150 mm (measured inner Ø 152 mm)
Print settings
Setting | Value |
|---|---|
Material | PETG (heat resistance); PLA works too |
Layer height | 0.16 mm |
Wall loops (perimeters) | 4 |
Top/bottom shell | 1.5 mm (4 layers), 100 % |
Infill | 100 % |
Supports | none |
Orientation | flange down (flat mounting face) |
Filament (intake) | ~150 g |
Hardware / components
All ducting parts are from the HACO Ø150 system (photos in the gallery). Type codes make them easy to source.
Fasteners | Part | Item | |---|---| | Intake adapter → AC | 9× M3 × 10 mm hex (Allen) + M3 nylon-insert lock nuts (nyloc) — the AC vibrates, locking nuts prevent loosening. One hole needs a washer (lands over an open grille area) | | Exhaust brackets → plywood | 3.5 × 16 mm Torx countersunk wood screws | | Grille sealing | duck tape (simplest option — not pretty; better solution TBD) |
Ducting (required) | Part | Type | |---|---| | Aluminium flex hose Ø150 | HACO AL FLEXO 150 (2.5 m; inner Ø 152) | | Hose clamp 140–160 mm | HACO HS W1 150 (Nr. 0612) |
Ducting (optional / installation-dependent) | Part | Type | |---|---| | Backflow flap (non-return damper) | HACO ZKK 150 (galvanised) | | Outside vent grille w/ mesh | HACO VM 150 B (Nr. 0401) | | PVC coupler / cuff | HACO CVO 157 (Nr. 0652) | | 90° PVC elbow Ø150 | HACO CKO 150 | | Rigid PVC pipe Ø154 | HACO V 154×500 (as needed for your routing) | | Pipe holder / clip | HACO UMO 150 (2 pcs) |
Installation
Unscrew and remove the AC cover.
Remove the filter mesh from the back.
Trim the protruding grille rim sections where the nuts will sit (shave only the ~1 mm raised rim, not the grille/ribs).
Drill the mounting holes.
Screw on the intake adapter (9× M3 × 10 + nyloc nuts). One hole lands partly over an open grille area — use a washer there.
Seal the remaining grille area (otherwise the AC draws room air instead of ducted outside air).
Refit the cover back onto the AC.
Slide the aluminium flex hose over the neck (seats at the neck-to-cone shoulder).
Secure with the hose clamp.
Parameters (edit in the FreeCAD Params spreadsheet)
Naming convention: part_dimension — _l length, _w width, _h height/thickness, _d diameter, _f fillet, _ch chamfer.
Intake adapter
Param | Value | Meaning |
|---|---|---|
flange_w | 150 | flange width |
flange_l | 214 | flange length |
flange_h | 3 | flange thickness |
flange_f | 1.5 | flange edge fillet |
opening_w | 123 | intake opening width |
opening_l | 200 | intake opening length |
opening_f | 15 | opening corner fillet |
cone_h | 60 | cone (transition) height |
cone_f | 2 | cone fillet |
neck_d | 151 | neck outer Ø (fits both alu flex hose and rigid pipe) |
neck_h | 40 | neck length |
neck_f | 0.8 | neck mouth chamfer base (lead-in chamfer = neck_f × 2) |
wall | 2 | shell wall thickness |
hole_d | 3.5 | mounting hole Ø (enlarged for print seam so M3 passes cleanly) |
screw_hole_inner_d | 12 | AC-screw access tunnel bore |
screw_hole_outer_d | 16 | access tunnel boss OD |
Exhaust brackets
Param | Value | Meaning |
|---|---|---|
opening_l | 220 | opening length |
opening_w | 102 | opening width |
outer_d | 101 | collar outer Ø |
outer_h | 20 | collar height |
outer_offset | 8.8 | offset |
outer_gap | 1.8 | gap |
ear_gain | 13.4 | ear extension |
ear_d | 7 | ear Ø |
foot_l / foot_w / foot_h | 100 / 50 / 5 | foot |
hole_d | 4 | screw hole |
hole_ch | 2.5 | screw countersink |
Tip: to fit a different hose, measure the hose inner diameter and set
neck_daccordingly.
Tolerance note
neck_d is 151 mm — test-printed to fit both the Ø150 aluminium flex hose and a rigid plastic pipe snugly. The neck has a lead-in chamfer (neck_f × 2) for easier insertion, and the neck-to-cone shoulder acts as the hose stop. hole_d was enlarged to 3.5 mm so the print seam doesn't make the M3 screws bind. Aluminium flex hoses vary — measure yours and adjust neck_d if needed.
Changelog
v1.1 — neck_d 151.5 → 151 (fits alu flex + rigid pipe); mounting holes 3.2 → 3.5 (print-seam clearance); neck fillet replaced by a lead-in chamfer (neck_f × 2); added grille-sealing note and full installation steps.
v1.0 — initial release.
Files
3MF — ready to print
STEP — for editing in any CAD
FCStd — native FreeCAD 1.1, fully parametric (edit
Params)
Feedback
Made for one specific unit and shared in case it helps someone with the same AC. Comments, prints and remixes welcome.
Keywords (SK/CZ): mobilná klimatizácia, mobilní klimatizace, adaptér nasávania, výfuk, hliníková flexi rúra Ø150, redukcia, Whirlpool PACF212HP, parametrický model, FreeCAD, PETG, spätná klapka.
Designed in FreeCAD 1.1 · License: CC BY-NC-SA 4.0