Velta Underfloor Heating Manifold Adapter – M30x1.5 Female Port to Standard Thermal Actuator (Parametric)
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
Sleeve + plunger to fit standard M30x1.5 thermal actuators on old Velta UFH manifolds. Parametric OpenSCAD.
- Ocena
- 0 / 5
- Polubienia
- 0
- Pobrania
- 1
- Wydruki
- 0
- Wyświetlenia
- 11
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Other House Equipment
- Licencja
- Creative Commons — Attribution — Share Alike
Old Velta (now Uponor) underfloor heating manifolds have their thermostatic valves sitting deep inside a female M30x1.5 thread. Standard thermal actuators (230 V / 24 V, NC or NO) come with an M30x1.5 union nut and expect a male thread with the valve pin close to the top, so they don't fit. Original actuators or brand adapters are expensive and hard to find.
This adapter solves it with two simple printed parts:
Threaded sleeve: continuous M30x1.5 male thread, 24 mm long. The lower part screws into the manifold, the upper part takes the actuator's union nut. A 10 mm hex socket on top lets you screw it in with an Allen key.
Plunger: a loose 6 mm pin (4 mm tip) running in the sleeve's bore, transferring the actuator stroke down to the deep-seated valve pin.
I use it with generic 230 V NC actuators (M30x1.5, 4 mm stroke) switched by Sonoff NSPanel relays / Home Assistant for room-by-room floor heating control.
Measure before you print - the plunger length matters
Valve and actuator geometry varies. The included 35 mm plunger fits my manifold and my actuators. Check yours:
Manifold: remove the cap, screw the sleeve in to the stop. Measure from the sleeve top down to the valve pin: V_closed = pin pushed in fully, V_open = pin released.
Actuator: screw the actuator onto the sleeve to the stop. Measure from the sleeve bottom through the bore to the actuator pin and subtract the sleeve length (24 mm): A_ext = pin extended (NC actuator unpowered - release the "first open" lock first!), A_ret = pin retracted (powered).
Valid plunger length: V_closed + A_ext <= L <= V_open + A_ret. Pick a value slightly above the minimum so the valve closes fully with some preload.
My values: 25.1 + 9.0 = 34.1 <= L <= 22.4 + 13.7 = 36.1, so L = 35 mm.
Set plunger_length in the OpenSCAD Customizer and export your own STL. All other dimensions (thread clearance, pitch, sleeve length, bore, hex size, tip diameter) are parameters too, so this may also work for other manifolds with a female M30 port. No libraries needed.
Testing
Actuator unpowered (NC): the circuit must go cold.
Actuator powered: after 3-5 minutes the circuit must get warm again.
Old valves can have weak return springs - check that they really open.
Print settings
Material: PETG or ASA (PLA not recommended, the manifold area gets warm)
Layer height 0.15-0.2 mm, 4 perimeters, 40 %+ infill, no supports
Sleeve standing (hex socket up), plunger standing with brim
Thread fit: default clearance 0.35 mm on diameter, adjust clearance_d if too tight or loose
Disclaimer
DIY part for a heating system. The sleeve is not wetted and not pressurised, it only holds the actuator. Don't touch the return-side balancing valves. Use at your own risk.