Templates for penciling a cut line for dry wall cut out for low voltage brackets

Ocena
5 / 5
Polubienia
23
Pobrania
246
Wydruki
2
Wyświetlenia
713
Oceny
3

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Kategoria
Electronics
Licencja
Creative Commons — Public Domain

UPDATE Nov. 12, 2025 : Per the suggestion of “Troy” in the comments, I have added versions with notches (center marks) - these are the “02” version files.

UPDATE Nov. 14, 2025 : To make the “center mark” versions easier to use with a level, I added an addition modification - these are the “03” files with additional “bumps” added to enable a level to align easily..

Recently I was installing some Ethernet jacks, so I designed these templates to help with mounting the required low voltage brackets in dry wall. 

CAUTION : I printed and tested only the single gang version of this print. The double and triple gang versions were designed based on CAD models of the corresponding brackets, but since I did have not any of these I did not make test prints. 

These templates are designed to serve as a template for penciling a line on dry wall so that an opening can be cut out for a low voltage bracket. They have these features:

  • The opening in the template corresponds to the hole size that needs to cut in the dry wall for the low voltage bracket.
  • The outside outline of the template is the same size as the wall plate needed for the bracket.
  • Each template has a “right-angle side” - this is intended to be used with a bubble level to level the template before tracing the inside opening with a pencil.

Use

  1. Position the template in the desired location for the bracket, while holding a bubble level against the right angle side (see photos).
  2. When the template is in the correct position (and level), use a pencil to trace the inside of the template on the dry wall.
  3. Use a drywall saw to cut an opening by cutting on the pencil line.
  4. Install the low voltage bracket.