Containers and adapter plates for silica beads to decrease the humidity within COY anaerobic tents.

Ocena
0 / 5
Polubienia
1
Pobrania
17
Wydruki
0
Wyświetlenia
168
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Licencja
Creative Commons — Attribution — Noncommercial

Anaerobic tent is the equipment for work with microorganisms in the absence of oxygen. For such purpose there are catalyst boxes (a.k.a. oxygen scrubbers) where oxygen is converted into water via catalyzed reaction with hydrogen. The produced water vapor may build-up within anaerobic tent as not needed humidity. The accumulated humidity is typically removed with silica beads packs and their further regeneration at 130°C in drying oven. We have a compact version from COY, where the space is limited, and such this mini project has started:

  • put the silica beads closer to the gas flow in within anaerobic tents
    • tried to put in the flow on top of catalyst box
  • make a container (or cartridge) to contain desiccant
    • also needed some adapter placts to prevent fall off the support surface
  • this container should be easily swapped with the fresh one, and placed into regeneration
  • the material of container should withstand the regeneration process without damage.

Optionally:

  • it would be nice to have a slot for some sort of humidity indicator (some cheap mass-market indicators would be sufficient)

Encountered issues:

  • placing desiccant box on top of the catalyst box decreases the flow-through, and thus, slows down the work of oxygen scrubbers
    • it affects the maximum container volume
    • needed to play around with vent geometry of bottom and the lid
    • also created a version when container is a bit elevated, but that should be printed with supports
  • there are a few filaments that can survive long-term storage 130°C drying oven 
    • ended up with polycarbonate filament (PC/PBT mix)
    • however, it shrinks and changes color over time. Thus use as:
      • print
      • fill with desiccant
      • assemble (screw the lid)
      • put assembled to the drying oven
  • the silica beads are often arrived cracked
    • this forces to make narrower ventilation slots on the bottom, consecutively, decreasing the flow through the holder.
  • polycarbonate filament need some help to be stick to the print bed on this size of parts
    • used DimaFix spray

After some try-outs, we find-out the "slot width / rib width " ratio where the loss of gas flow was acceptable. However, the thickness of silica beads layer is the main factor affecting the flow. Thus, the smaller version of container (300ml) is preferable to use with adapter plate without elevation. Other size option are still usable, but in such case it would be better to use with elevated baseplates or to replace the fan in the catalyst box for one that can achieve higher gas flow rates. These holders were tested with 3mm silica beads, and worked well. However some fraction of cracked beads are still falling down through the bottom mesh.

NB!: older versions of COY catalyst box has the cable inlet from the top. Thus some extra electrical work/cable management is required and that might void your warranty.

 

Needed fixture to assemble: 3.5 screws (~12 mm long would be sufficient)

Designed in Solidworks 2021. These models were designed as part of work at Wageningen University and Research.