Rittal 7240.210 powerCON TRUE1 TOP Inlet-Outlet Module
We calculate the final price from your selected file. You review and accept it before payment.
Saved on this device.
Add a Neutrik powerCON TRUE1 TOP Inlet-Outlet to your Rittal DK 7240.210 PDU!
- Rating
- 0 / 5
- Likes
- 5
- Downloads
- 23
- Makes
- 0
- Views
- 374
- Reviews
- 0
Updated at source:
Model information
- Source
- Printables
- Category
- Electronics
- License
- Creative Commons — Attribution — Noncommercial
This part replaces the blanking plate in the modular 19" Rittal DK 7240.210 PDU with a module that can hold a Neutrik NAC3PX-TOP inlet-outlet.
Installing it involves removing the fixed cable. Obviously, you can recycle the cable with a powerCON TRUE1 Outlet like NAC3FX-W-TOP or the newer NAC3F-TRUE1-S.
DO THIS MODIFICATION AT YOUR OWN RISK! I am not an electrician. If this happens to be the reason your house burns down, I am not at fault. Get an electrician to do it for you or at least to sign off on it. This is not electrical advice. You have been warned.
Print settings:
- 0.2mm Layer height
- Supports from build plate
- 3 Perimeters
- 15% infill is fine
- Material of your choice. I used PLA, but a more stiff and heat resistant material like PC might be better. YMMV.
Necessary parts:
- 1 Neutrik NAC3PX-TOP
- 2 insulated ¼" flat tab terminal crimps (Red)
- 1 uninsulated ¼" flat tab terminal crimps (Red)
- 1 WAGO 221-413 for Outlet PE and Chassis PE
- 4 ruthex RX-M3x5.7 M3 heat inserts
- 4 counter-sunk M3x10 or M3x8 screws
- Short PE wire
Necessary tools:
- Deburring Tool
- PZ1 screwdriver for opening Rittal 7240.210
- PH1 screwdriver for mounting Rittal 7240.210
- Appropriate screwdriver for the M3 screws (Torx or hex!)
- Wire crimper
- Wire cutter
- Wire strippers (if you need them)
Instructions for qualified personel only:
- Clean up the part, use the deburring tool to remove support and brim if used.
- Open PDU side that has the original cable.
- Remove blank plate and ensure the 3D print fits!!
- Insert the M3 inserts into the 3D print, use NAC3PX-TOP to confirm fit.
- Remove cable from terminal block and end piece.
- Cut the crimped ends off of the wires coming from the Schuko sockets.
- Crimp insulated spades to L and N coming from the sockets.
- Wire PE from sockets and chassis ground to 221-413.
- Crimp uninsulated spade to short PE wire and attach to 221-413.
- Insert printed part and pull spades through.
- Insert NAC3PX-TOP into print, ensure wires are properly connected and routed, then fix it with the M3 screws.
- Close up with original cable holder end piece (sans cable, obviously)
- Perform full electrical safety tests.