1 / 9
K1C chamber heater for  heater 300W — image 1
1 / 9

K1C chamber heater for heater 300W

Order a print of this model

We calculate the final price from your selected file. You review and accept it before payment.

Saved on this device.

Only the lower part was modified

Rating
0 / 5
Likes
41
Downloads
103
Makes
0
Views
1,227
Reviews
0

Updated at source:

Model information

License
Creative Commons — Attribution — Noncommercial — Share Alike

Heater 300W - link

Please see the schematic in the attached file.

 Below is my code in printer.cfg

#  MCU: Klipper Expander
# External MCU (Klipper Expander board) connection
[mcu expander]
serial: /dev/serial/by-id/usb-Klipper_stm32f042x6_130011001653304B4D323431-if00
restart_method: command

=========================

Нагреватель камеры (SSR)

=========================

300 Вт / 220 В через SSR, управление с PA3 на Expander

=========================

Chamber heater (SSR)

=========================

300 W / 220 VAC heater through an SSR, controlled from PA3 on the Expander

[heater_generic chamber] heater_pin: expander:PA3 sensor_type: EPCOS 100K B57560G104F sensor_pin: PC5 control: pid min_temp: 0 max_temp: 80 max_power: 1.0 # при необходимости можно снизить, например 0.6 You can limit heater power if needed (e.g. 0.6) pwm_cycle_time: 0.10 # медленный PWM для SSR (~10 Гц) Slow PWM for SSR (~10 Hz)

PID-параметры (стартовые, потом можно подстроить)

PID parameters (starting values; fine-tune later)

pid_Kp: 63.418 pid_Ki: 1.342 pid_Kd: 749.125

Безопасность нагревателя

Heater safety checks

[verify_heater chamber] max_error: 400 check_gain_time: 600 hysteresis: 5 heating_gain: 2

==================================

Вентилятор-улитка 24 В

==================================

Управление по PWM с PA0 на Expander

=========================

24V blower fan (snail/centrifugal)

=========================

PWM control from PA0 on the Expander

[fan_generic chamber_heater_fan] pin: expander:PA0 max_power: 1.0 hardware_pwm: false # высокочастотный аппаратный PWM для тихой работы Use software PWM (hardware PWM would be high-frequency) cycle_time: 0.00005 # PWM period (lower = higher frequency) shutdown_speed: 0.0

============================================

Логика работы улитки по температурным зонам

и состоянию нагревателя камеры

============================================

Blower control logic based on chamber target/temp/heater

[gcode_macro UPDATE_CHAMBER_HEATER_FAN] description: Обновление скорости улитки по температуре камеры и мощности нагревателя gcode: {% set h = printer["heater_generic chamber"] %} # Current heater output (0.0..1.0) {% set pwm = h.power|float %} # Current chamber temperature {% set t = h.temperature|float %} # Current chamber temperature target {% set target = h.target|float %} # Blower speed to apply (0.0..1.0) {% set speed = 0.0 %}

Если в слайсере задано 45°C или меньше — считаем, что нагрев камеры не нужен

If slicer target is 45°C or lower, assume chamber heating is not needed

{% if target <= 45 %} # выключаем нагрев камеры # Turn chamber heater off SET_HEATER_TEMPERATURE HEATER=chamber TARGET=0 # вытяжной вентилятор по температуре тоже отключаем # Also disable the exhaust temperature fan logic (set a low/default target) SET_TEMPERATURE_FAN_TARGET TEMPERATURE_FAN=chamber_fan TARGET=40 {% set speed = 0.0 %}

{% else %} # Нагрев нужен. Температура включения/контроля выдува = target + 5°C # Heating is required. Exhaust fan target = chamber target + 5°C {% set fan_on_temp = target + 5.0 %}

  # Обновляем цель для temperature_fan chamber_fan
  # Update the target for temperature_fan "chamber_fan"
  SET_TEMPERATURE_FAN_TARGET TEMPERATURE_FAN=chamber_fan TARGET={fan_on_temp}

  # Минимальная и максимальная скорость для улитки над нагревателем
  # Min/max blower speed (above the heater)
  {% set min_speed = 0.40 %}
  {% set max_speed = 1.00 %}

  {% if pwm &gt; 0.01 %}
      # Нагреватель сейчас греет — скорость зависит от мощности нагревателя
      # Heater is actively heating: scale blower speed with heater power
      {% set raw_speed = min_speed + (max_speed - min_speed) * pwm %}

      {% if raw_speed &lt; 0.0 %}
          {% set speed = 0.0 %}
      {% elif raw_speed &gt; 1.0 %}
          {% set speed = 1.0 %}
      {% else %}
          {% set speed = raw_speed %}
      {% endif %}

  {% else %}
      # Нагреватель выключен — логика по фактической температуре камеры
      # Heater is off: use temperature-based logic
      {% if t &gt;= fan_on_temp %}
          {% set speed = 0.30 %}          # камера выше target+5 → добдуваем Above target+5 → keep blowing a bit
      {% elif t &gt;= fan_on_temp - 10 %}
          {% set speed = 0.20 %}          # зона target-5..target+5 → лёгкий выдув  Around target (roughly target-5..target+5)
      {% else %}
          {% set speed = 0.0 %}           # ниже → улитка выключена Below → blower off
      {% endif %}
  {% endif %}

{% endif %}

SET_FAN_SPEED FAN=chamber_heater_fan SPEED={speed}

Периодический вызов обновления вентилятора

Periodic fan update loop

[delayed_gcode CHAMBER_HEATER_FAN_LOOP] initial_duration: 2.0 gcode: UPDATE_CHAMBER_HEATER_FAN UPDATE_DELAYED_GCODE ID=CHAMBER_HEATER_FAN_LOOP DURATION=2.0

Cancel print hook (ensure chamber is off)

[gcode_macro CANCEL_PRINT] rename_existing: BASE_CANCEL_PRINT gcode: END_PRINT
# Force chamber heater off SET_HEATER_TEMPERATURE HEATER=chamber TARGET=0 # Reset exhaust temperature fan target SET_TEMPERATURE_FAN_TARGET TEMPERATURE_FAN=chamber_fan TARGET=40 BASE_CANCEL_PRINT

M142 support (set chamber temp from slicer)

[gcode_macro M142] description: Set chamber temperature from slicer gcode: {% set s = params.S|float %} SET_HEATER_TEMPERATURE HEATER=chamber TARGET={s} UPDATE_CHAMBER_HEATER_FAN

Tags