HaRVy
We calculate the final price from your selected file. You review and accept it before payment.
Saved on this device.
Low-cost, single-room HRV that brings in fresh air while saving on heating and cooling bills
- Rating
- 5 / 5
- Likes
- 16
- Downloads
- 9
- Makes
- 0
- Views
- 118
- Reviews
- 1
Updated at source:
Model information
- Source
- Printables
- Category
- Accessories
- License
- Creative Commons — Attribution — Noncommercial
Brief Overview
HaRVy is a Heat-Recovery Ventilation system (HRV). It was designed to allow printing ASA and other plastics with toxic fumes on days when it's to hot or cold outside to open a window. It also works to get rid of paint fumes, or just to freshen the air.
The air leaving the room transfers its heat to the air coming back in, resulting in almost no heat gain or loss, all while exchanging the actual air. This model uses sheets of aluminum foil for the heat transfer. Aluminum foil is 100's of times more thermally conductive than plastic, resulting in an extremely efficient heat transfer system.

Note that this is the main body only. HaRVy is designed to be modular to allow it to be adapted for different setups. Various attachments can be used to adapt to different needs. Some common attachments will be posted as separate models, and dimensions are published for people looking to customize their own systems.
How well it works
HaRVy 1.0.1 (the predecessor to this model) was measured to be a little over 80% efficient at 30cfm (0.85m³/min). At this rate, with my current gas prices, it would constitute around $2 per month to run continuously. Version 1.0.3 is slightly smaller -- it was shrunk by 15mm to fit on the INDX build plate. I expect it will likely be a little less efficient (I'll update this once it gets cold enough to do proper measurements).
The actual numbers are as follows: Measurements were taken when it was 20.6°C colder outside than inside (-0.7°C / 19.9°C ). The differential between outgoing and incoming air showed a difference of 3.7°C and 3.8°C when measured from inside and outside respectively. An anemometer was used to measure air speed, which was multiplied by the size of the opening to get just over 30cfm.
As far as radon goes, it doesn't have enough airflow to be overly effective to reduce these levels. It lowered my Radon from from 113 Bq/m³ to a little over 80 Bq/m³ (averaged over a two month span), so not huge, but it is better than nothing. Once I add some ducting to grab air from the floor level, it will hopefully improve on this number a bit more.
Considerations
Fans
There is an existing attachment to connect this to two standard 120mm computer fans (see links below). Other attachments can be made to accommodate other fan types. There are also attachments to connected to standard duct tubing.
Use one fan (pushing air out) if you are painting -- it is significantly less thermally efficient than two fans, but it creates negative pressure, which completely stops fumes from escaping from the room you're working in. Use two fans for regular use, or when running continuously. Always use two fans in a basement that might have radon (as negative pressure can increase radon levels).
I have been tempted to try connecting it to the output of my shopvac, but I'm a bit weary that that might produce enough force to tear the aluminum foil...
Duct Work
Ideally, you want the air intake to be far away from the air return. This prevents you from just recirculating the same air. You also need to insulate any duct work between the main body and the outside to maximize efficiency. By the same token, try to separate the air on the outdoor vents as well.
Condensation and Drainage
When planning how your ducting works, plan for condensation, both from ingress and egress air. HaRVy was specifically designed to allow condensation to work its way out of the main box, however, there is no drain on the main box itself.
Filter
I put a HEPA filter on the output of my ingress flow to prevent bugs and pollens from getting sucked into the house. Details, including the filter I used, are linked here. I am currently working on a setup with a larger filter (HPA300 filters in particular, which are bigger, and cheaper. I'll post this once I'm done that unit).
Gaskets or Caulking
When adding attachments, you need to use gaskets or caulking to prevent air leakage between the flows. I will publish the end gaskets in a separate model -- these must be printed with TPU or other flexible material.
Printing and Assembly
I am publishing models for use with both #6 and m4 screws, as I was informed that #6 screws are not common in Europe.
Required Parts
Printed Parts:
Left Layer (x1) and Right Layer (x1) - PETG, 20% Cubic infill. You can optionally delete the decals on the slicer if you do not have a multicolor printer, or if you do not want the text to stand out. Print on a Textured PEI sheet, for simpler removal.
Even Layer (x7), and Odd Layer (x7) -- PETG, 20% Cubic infill -- print on Flat PEI Sheet (helps with seal integrity). Let it cool down before removing, and remove very carefully -- with extra care taken around the ingress and egress vent meshes. You need seven of each of these
Bridge Couplers (x1 set of 8) - PETG , 100% infill
Roll of Heavy Duty Aluminum Foil -- 12"x10' (30cm x 3m). Cut into 15 180mm x 237mm sheets (+/- 2mm). Heavy duty foil is recommended.
Screws: 16 countersunk #6-32 bolts (at least 1" long) or m4 bolts (at least 25mm long)
A tap for above screws (not strictly needed, but highly recommended)
15mm or 3/4" bolts of the same type will likely be used for attachments later on.
Printing
This requires at least a 24.8cm x 20.5cm built plate (designed to print on a Core One with INDX)
Use a .4mm nozzle and .2mm layer height. The walls, floor and ceilings of the vents assume these settings. Use 2 perimeters, and Cubic Infill at 20% (for insulation purposes). Note that all of the pilot holes are reinforced, so the 2 perimeters will be sufficient for this. Do not print with supports.
Use PETG -- Avoid PLA as it can become to brittle in extreme cold. Avoid ABS/ASA as these will tend to warp during printing due to the large size of the parts.
Remove carefully from the build plate! The even/odd layers should be printed on a FLAT PEI sheet, making them stick. If, when removing these, the vent meshes in the middle tear, it is not a big deal -- simply make sure there are no sharp edges which can puncture the aluminum foil and you're good to go. If, on the other hand, one of the vent meshes at the ends tear, air will be able to work its way under the foil barrier at that point, and it may have a significant impact on efficiency -- you will need to reprint if this happens.
Assembly
Cut 15 sheets of aluminum foil using a paper cutter or scissors (180mm x 238mm, +/- 2mm) -- a knife will likely lead to tearing. Even the smallest of tears will will have a large impact on efficiency.

Start with the Left side, placed face down (so the join tabs are facing upwards). Place a sheet Aluminum foil on this, then alternate between even and odd layers, placing foil between the layers. Note that the vents should alternate between layers. Once you have this, add on the right layer to the top. Insert the bridges, and use your bolts to secure these into place. Note: there should be a 1mm gap between the bridge and the mounting nubs -- this is done on purpose. Tighten the bolts securely, but do not overtighten -- overtightening may result in the edge bowing near the middle, which can lead to air leakage.
Aluminum foil doubles as an effective sealant, so no need for any caulking between the pieces.
Accessories can be attached to the ends using either the side-mounted drawplates, or they can be screwed directly into the end. You may need a sealant between the accessories and the end -- you can use caulking or a gasket printed with TPU.
Drawplates and Gaskets are included in a separate model
Installation
HaRVy must be installed level, and upright with the This Side Up arrow pointing up. (Yes, it matters...)
Insulate any pipes between the unit and the window (or the unit and the outside) to prevent premature heat transfer. No insulation is required on any of the inside fittings.
Try to separate the intake and outtake on both the inside and outside to prevent recirculating the same air
Attachments
The following are some attachments available for this. I posted these as separate models, as this is meant to be modular, and I didn't want to clutter this model.
HaRVy End Gaskets and Drawplates -- end gaskets and drawplates for attaching most accessories.
HaRVy Double Fan Attachment -- attachment for two 120mm computer fans to HaRVy's main body
HaRVy Duct Attachments -- allows connecting any standard sized duct tubing (3", 4", 80mm, 100mm) directly to HaRVy's main body
Fan Duct Attachments -- allows connecting any standard sized duct tubing to 120mm computer fans
Fan Filter Attachment -- (to be published shortly) -- allows attaching a small HEPA filter to a 120mm computer fan.
Duct Adapters -- This is a customizer (not prebuilt models) allowing you to specify the size of any two ducts, and generating a model based on that. You need to download OpenSCAD (free) to use it. There are other published models which do similar things, but many of these are not sloped properly, which can result in buffeting and decreased air flow. For duct tubing, you want to specify male ends, and 0 taper on the connectors. To attach to the Fan Duct Attachments, specify female ends
Final words
This model has quite a bit of design in it -- there are a lot of subtle details to make it work right. But, that being said, I have no doubt it can be improved upon. If you have any requests or ideas for the main body, let me know.
If you do make a custom attachment you think others can use, please post it with a link back to this. If you have a change request let me know.
Outside of this, if you do make one of these, please post a make, and let me know your thoughts on it. Also, please do leave a like if you find the model interesting. It took quite bit of work to generate, and it would be nice to know it's appreciated.