1 / 1
IKEA SKÅDIS Mount for Zyxel XMG1915-10E – Ports Down — image 1

IKEA SKÅDIS Mount for Zyxel XMG1915-10E – Ports Down

Order a print of this model

We calculate the final price from your selected file. You review and accept it before payment.

Saved on this device.

Exact 176 mm keyhole adapter for mounting a Zyxel XMG1915-10E horizontally on an IKEA SKÅDIS pegboard.

Rating
0 / 5
Likes
1
Downloads
2
Makes
0
Views
33
Reviews
0

Updated at source:

Model information

Category
Office
License
Creative Commons — Attribution — Noncommercial — Share Alike

Overview (English)

This adapter mounts a Zyxel XMG1915-10E horizontally on an original IKEA SKÅDIS pegboard. The switch uses its factory keyhole mounting slots, so it can be installed with the network ports facing down, matching the recommended wall-mounting orientation.

The two mounting screws are positioned exactly 176 mm center-to-center. Six integrated SKÅDIS hooks distribute the load across the pegboard.

The design has been printed and successfully installed on an original IKEA SKÅDIS board. The pictured installation uses two M3×10 screws and two M3 nuts.

Features

- Exact 176 mm screw spacing for the Zyxel XMG1915-10E

- Horizontal switch orientation with ports facing down

- Six integrated IKEA SKÅDIS hooks

- Uses the switch's original keyhole mounting slots

- No modification of the switch required

- Fits a Bambu Lab P1S build plate

- Separate low-material hook test included

- Parametric OpenSCAD source included

Required hardware

- 2× M3×10 pan-head or socket-head screws

- 2× M3 nuts, preferably lock nuts

The STL has 4.2 mm through-holes, so slightly larger compatible screws can also be used if their heads fit the switch's keyhole slots. The tested installation uses M3×10 screws.

Leave approximately 2 mm clearance beneath each screw head, tighten the nut on the rear side of the adapter and then slide the switch down onto both screw heads.

Installation

1. Insert all six hooks into matching SKÅDIS slots.

2. Slide the complete adapter down by approximately 7 mm until it is seated.

3. Install both screws and nuts with 176 mm between the screw centers.

4. Set approximately 2 mm clearance beneath the screw heads.

5. Place the switch over both screw heads and slide it down.

6. The network ports must point down.

An optional cable tie can be used as a secondary anti-lift safeguard. Do not cover any ventilation openings.

Print settings

- Material: PETG recommended; ASA or well-printed ABS is also suitable

- Nozzle: 0.4 mm

- Layer height: 0.20 mm

- Perimeters/walls: 5

- Top and bottom layers: at least 5

- Infill: 30% Gyroid or Cubic

- Orientation: large flat front face on the build plate, hooks facing up

- Supports: build plate only / organic or tree support beneath the rear hook tongues

- Brim: 5 mm recommended

The adapter measures 220 × 70 × 16.6 mm.

Print skadis_haken_test.stl first if you use a different material, a differently calibrated printer or a non-original pegboard. When removing supports, cut them into small sections and support each hook with a finger. Do not twist or lever off the complete support tree, as this can break a hook.

Compatibility

Verified:

- Zyxel XMG1915-10E

- Original IKEA SKÅDIS pegboard

The adapter has not been verified with other Zyxel models, even if their enclosures look similar.

Safety

Check all hooks after printing and after removing the supports. Do not use the adapter if a hook is cracked or partially detached. Recheck the mounting after the first days of use.

Übersicht (Deutsch)

Diese Adapterplatte befestigt einen Zyxel XMG1915-10E waagerecht an einer originalen IKEA-SKÅDIS-Lochplatte. Der Switch wird über seine werkseitigen Schlüssellochaufnahmen eingehängt. Dadurch können die Netzwerkanschlüsse nach unten zeigen, entsprechend der vorgesehenen Wandmontage.

Die beiden Schrauben sitzen exakt 176 mm Mitte–Mitte auseinander. Sechs integrierte SKÅDIS-Haken verteilen das Gewicht auf der Lochplatte.

Das Modell wurde gedruckt und erfolgreich an einer originalen IKEA-SKÅDIS-Platte montiert. Für die getestete Installation wurden zwei M3×10-Schrauben und zwei M3-Muttern verwendet.

Merkmale

- Exakter Schraubenabstand von 176 mm

- Waagerechte Montage mit Ports nach unten

- Sechs integrierte SKÅDIS-Haken

- Nutzung der originalen Schlüssellochaufnahmen

- Keine Veränderung des Switches erforderlich

- Passt auf das Druckbett des Bambu Lab P1S

- Materialsparender Hakentest enthalten

- Parametrische OpenSCAD-Quelldatei enthalten

Benötigtes Material

- 2× M3×10-Schraube mit Linsen-, Flach- oder Zylinderkopf

- 2× M3-Mutter, vorzugsweise selbstsichernd

Unter jedem Schraubenkopf ungefähr 2 mm Abstand lassen, die Mutter auf der Rückseite festziehen und anschließend den Switch auf beide Schraubenköpfe setzen und nach unten schieben.

Druckeinstellungen

- Material: vorzugsweise PETG; ASA oder sauber gedrucktes ABS ebenfalls geeignet

- Düse: 0,4 mm

- Schichthöhe: 0,20 mm

- Wände: 5

- obere und untere Schichten: mindestens 5

- Infill: 30 % Gyroid oder Cubic

- Ausrichtung: große glatte Vorderseite aufs Druckbett, Haken nach oben

- Support: nur vom Druckbett, Organic/Tree unter den hinteren Hakenzungen

- Brim: 5 mm empfohlen

Bei einem anderen Material oder Drucker zuerst skadis_haken_test.stl drucken. Supports in kleinen Abschnitten mit einem Seitenschneider entfernen und den jeweiligen Haken dabei abstützen. Den vollständigen Supportbaum nicht verdrehen oder abhebeln.

Tags