Retrofit for the Aereco ZFH 5-35 moisture-controlled external air vent or as spare parts for the ZFHV 5-35 with lever.

Rating
0 / 5
Likes
1
Downloads
32
Makes
0
Views
569
Reviews
0

Updated at source:

Model information

License
Creative Commons — Attribution — Share Alike

Use as retrofit kit  for the Aereco ZFH 5-35 moisture-controlled external air vent or as spare parts for the ZFHV 5-35 with lever.

The pin and shutter lever converts the ZFH 5-35 to the ZFHV 5-35 and allows for a manual override of the air vent. 

The opening and closing lever offers 3 opening positions:

  • Left - minimum (basic ventilation)
  • Center - automatic (humidity control)
  • Right - maximum

 

To install the retrofit kit in the ZFH 5-35 without a shutter lever you must 

  1. drill a 11 mm hole in the cover where the grey hole in the insert is. 
  2. Install the pin in the grey insert hole, looking to the left. 
  3. Then mount the insert and close the cover. 
  4. Finally install the lever from the outside. 