Ratrig V-Core 4 Replacement AC cover for use with dual channel Carlo Gavazzi SSR
- Ocena
- 0 / 5
- Polubienia
- 3
- Pobrania
- 16
- Wydruki
- 0
- Wyświetlenia
- 258
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Other Printer Parts & Upgrades
- Licencja
- Creative Commons — Attribution
Liability Disclaimer:
This design relates to parts intended to guard from live AC power. If you don't know what you are doing, do not proceed. In fact, don't wire the RatRig. Have it done by a certified professional. Incorrect wiring or use of this design may be potentially dangerous or even lethal. No warrant of safety or serviceability or liability for results in the use of this design is taken by the creator. It is your responsibility to use proper materials and assess AC safety needs in the use of, or modification of, this design in any way.
Downloading and using this design means that you accept the responsibility for your own safety. If you burn your house down…really sorry. But that's on you. If the RatRig burns your house down, it's no different.
In theory, this design is no better or worse from a safety perspective than the one RatRig provides for the VC4.
------------------------------------------------------------------------------------------------
What is it?
- This new AC cover provides protection from AC mains terminals and connections when using a Carlo Gavazzi dual channel SSR. The RatRig one doesn't fit.
- If you choose to upgrade your VCC4 to a 20A IEC-320 C20 and a 20A fuse holder, as I did, that's also covered, so to speak.
- This AC cover installs on the original, stock Ratrig hex standoffs intended for the RatRig AC cover.
Why this weird SSR?
The Carlo Gavazzi dual channel 50A SSR, model RKD2A23D50P, is essentially (2) SSR's in one housing. It fits in the same place as the RatRig-provided standard SSR, using the same mounting screws and locknuts.
- One channel can be used for the AC-powered bed heater
- A 2nd channel can be used for an AC-powered chamber heater.
- The 24V DC input wires for controlling the (2) pole sets fit into a spring-loaded connector on top of the SSR.
- The original RatRig flat cover will not clear the top of the SSR or the DC input wires.
The C-LIN, Panasonic, and Omron single channel SSR's have AC mains only on the left-most bed cable terminals when installed per RatRig's design. The right side terminals are low voltage DC from the Octopus board. RatRig's AC cover leaves those terminals exposed, which is okay for low voltage DC, but not for AC mains.
SSR Features
- This dual channel SSR has AC mains power on the terminals of both left and right sides of the SSR. These both need to be protected.
- A wider cover was created which extends further to the right, over those terminals.
- We elected to keep the T1 and T2 (load) side of the SSR facing to the left, towards the bed power leads.
- AC mains go into L1 and L2, which are on the right side.
- It may not pass the UL finger probe test, so don't stick your fingers under the cover to test voltage, ok?
- The SSR DC control connector and DC leads stick above the SSR
- A hump in the cover provides clearance over the top of the connector used for the DC control wires
- Space is provided below the connector for those wires to be easily routed
Fuse Features
- When both the bed and heater are active, the current draw will exceed the rating of the IEC320 C14 receptacle and fuse holder that RatRig provides. Neither were UL registered components.
- A 20A Schurter power module with receptacle and switch were installed in an enlarged hole cut into the aluminum side panel. You will need an IEC320 C20 cable as the G, L, N pins are oriented differently.
- An Eaton fuse holder was relocated as shown, since the switch module took up the space where the fuse holder used to reside.
- This created another problem for the original cover.
- A raised channel was provided to protect the fuse holder as well.
Minor Change - One of the 3mm mounting holes in the original RatRig AC cover design is not used. This is the one across the top, centered over the PSU terminals. It is not in this design.
Six variants are provided depending on your needs. 3 versions, each with and without the DANGER text on them:
- AC cover with Fuse and SSR clearance
- AC cover with Fuse clearance only
- AC cover with SSR clearance only
Printing:
Recommend use of non-conductive ABS, ASA which are inherently HB rated for flammability. The cover is not in direct contact with any of the terminals or connections, but it's a wise precaution. DO NOT USE CF filled materials as some can be slightly electrically conductive. Most are not, but there's no benefit here.
30% cubic infill, organic tree supports seem to work best.
Parts Used:
- Carlo Gavazzi RKD2A23D50P dual channel 50A SSR
- Schurter EC11.0001.001 IEC320 C20 power module - combo switch w/receptacle
- IEC320 C20 Cable - find a UL listed one.
- Eaton BK/HTB-36I-R 20A fuse holder
- Eaton BK/MDA-20-R 20A fuse