Under Desk Mount QUBE 500
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
Robust under-desk mount for the Cooler Master QUBE 500, removable from the case with only 2 screws
- Ocena
- 0 / 5
- Polubienia
- 2
- Pobrania
- 10
- Wydruki
- 0
- Wyświetlenia
- 117
- Oceny
- 0
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Computers
- Licencja
- Creative Commons — Attribution — Noncommercial — Share Alike
Overview — Features & Advantages
This is a robust under-desk mount for the Cooler Master QUBE 500, designed to securely hold the PC while still allowing easy removal for maintenance or transport.
Only two screws attach to the stock threads and need to be removed to return the case to its original, stock configuration — ideal if you want to take the PC to a LAN party or move it frequently.
The mount uses the included rear handle of the QUBE 500 as a primary attachment point and provides good clearance for the front USB ports and audio jack.
Additional advantages:
Keeps the PC off the floor
Easier cleaning under the desk
Less dust, hair, and debris entering the case
Compatible with front exhaust setups to avoid heat buildup under the desk
Once installed, the top of the PC sits approximately 123 mm below the desk.
READ THE WHOLE DESCRIPTION IF YOU DECIDE TO PRINT THIS.
Compatibility & Use Case
Designed specifically for the Cooler Master QUBE 500
Fully compatible with my QUBE 500 front duct / shroud
Allows a front exhaust configuration
Helps prevent heat from being trapped under the desk
Hardware, Materials & Tools Required
Desk Requirements
Designed for a 25 mm thick tabletop
If your desk is thinner or thicker, different screw lengths can be used
⚠ Important:
If you have a hollow desk, the screw attachment will be significantly weaker. Use extra caution.
Screws & Hardware
Desk mounting (per hook)
2× 35×4 mm wood screws
With this setup, approximately:
20 mm of screw engages the desk in the front hooks
18 mm engages the desk in the back and locking hooks
The 35 mm screws are plenty strong for solid wood.
Leaving 5–10 mm from screw tip to desk surface is recommended to avoid damage or visible bumps.
Case mounting
2× M4 15 mm screws
2× 13 mm diameter washers
Only these two screws are required to remove the PC and return it to stock.
Tools Required (Very Important)
You must use a long-shaft screwdriver for the wood screws.
Phillips screws used
122 mm shaft screwdriver was just enough for the rear handle hooks.
⚠ Without a long-shaft tool, installation will not be possible.
Files to Print / Part Overview
Front_case_hooks.stl
The only parts that attach directly to the PC case
Mount to the QUBE 500 using the rear handle
Require only 2 × M4×15 mm screws and 13mm diameter washers to attach and remove the PC
Front_desk_hook.stl
Standard front desk hook
Use this if you do not need lateral locking
Front_desk_hook_with_lock.stl
Front desk hook with a side-lock feature
Required if you use only one Back_Handle_Hook
Prevents the case from sliding sideways out of the mount
Back_Handle_Hook.stl
Rear hook that attaches to the desk and interfaces with the QUBE 500 back handle
Can be used:
Alone (centered, requires at least one locking front hook)
In a pair for additional support
Recommended Mount Configurations
✅ Recommended Setup (balanced & simplest)
2 × Back_Handle_Hook
2 × Front_desk_hook
1 × Front_case_hooks
Provides good stability without requiring locking hooks.
🔒 Locked Setup (maximum security)
2 × Back_Handle_Hook
2 × Front_desk_hook_with_lock
1 × Front_case_hooks
Best option for pcs that could be bumped or if you want maximum resistance to sideways movement.
⚠ Minimal Setup (NOT recommended)
1 × Back_Handle_Hook
1 × Front_desk_hook
1 × Front_desk_hook_with_lock
1 × Front_case_hooks
Works, but has less redundancy and higher stress on each hook.
Use only if material is very limited and if you feel confident it will be enough.
Printing Settings & Materials
Material
ABS (used and recommended)
Do NOT use PLA
PLA may soften due to internal PC temperatures
This is a structural part
Base Print Settings
4 walls (0.6 mm each)
35% gyroid infill
~5 top & bottom layers (0.2 mm each)
Support only required for the Front_case_hooks (if printed in the original fila orientation)
Reinforced Sections (Modifiers Required)
I used modifiers for 100% infill in critical areas
(method may vary depending on your slicer).
Reinforced areas:
Top of the Front_case_hooks, where the M4 screws attach to the case
Approximately 84 mm and up (based on the shared file orientation)
Top section of all hooks, where the wood screws attach
Reinforce the top 18–20 mm
“Top” refers to the installed orientation, not the print orientation
Printing Orientation & Adhesion
Recommended to print hooks lying on their sides
Bed adhesion tabs are strongly recommended
Used 20 mm diameter cylinders, 0.8 mm height
All parts are oriented in my recommended print orientation, except:
The locking hook, oriented to avoid supports
(this orientation may not be the strongest)
Use your own judgment for orientation and slicer settings.
Installation & Clearance
The top and front panels can be installed and removed using a slight angled motion
(insert one side first under the printed part, then rotate the other side into place).
Clearances are very tight, but this can be easily corrected with sanding in specific areas if needed.
Warping, Measurements & Installation Accuracy
The values below are theoretical. Slight variation will only cause minor misalignment.
An image with the measurements is attached (top = back hooks, bottom = front hooks).
Warping must be carefully managed, especially on the back hooks
Installation accuracy is critical:
Front and back hooks must be parallel to each other and to the desk
Gap between back hooks: ~128 mm
(each hook offset by 2.8 mm to clear the rounded handle)Gap between front hooks:
133.6 mm (two non-locking)
129.6 mm (one locking + one non-locking)
125.6 mm (two locking)
Incorrect positioning will cause uneven stress and may lead to failures.
After printing the Front_case_hooks, I strongly recommend measuring them while attached to the case to confirm accuracy.
Hook contact faces with desk:
Non-locking: 25 mm deep × 42 mm wide
Locking: 25 mm deep × 50 mm wide
(includes 2 mm clearance + 2 mm locking wall on each side)
Installation Notes & Safety Warnings
Do NOT overtighten the wood screws
Overtightening can introduce excessive stress
This may cause layer separation or cracking
Tighten only until the hook is firmly secured to the desk
Disclaimer
I take no responsibility for any damage to your property.
I am currently using this mount and it works well for me, but I cannot guarantee it will work safely in every setup.
Use your own discretion, verify your materials, desk construction, and installation accuracy, and only use this mount if you are confident it is suitable for your setup.