Withings Body+ – Body Analysis Repair Kit / – Körperanalyse Reparatur Set
We calculate the final price from your selected file. You review and accept it before payment.
Saved on this device.
Fix body analysis failures caused by broken contacts. / Behebt Ausfälle der Körperanalyse durch defekte Kontakte.
- Rating
- 0 / 5
- Likes
- 0
- Downloads
- 2
- Makes
- 0
- Views
- 29
- Reviews
- 0
Updated at source:
Model information
- Source
- Printables
- Category
- Home Medical Tools
- License
- Creative Commons — Attribution — Noncommercial
English:
Repair Kit for Withings Body+ Scale – Restore Body Composition Analysis
This repair kit is for the Withings Body+ scale, for cases where the body analysis function (measurement of body fat, muscle mass, and water content) is no longer working correctly.
A common cause of this issue is broken or damaged electrical contacts inside the scale. In such cases, the scale may still display body weight correctly, but the bioelectrical impedance analysis can no longer operate properly.
With this repair kit, the defective contact parts can be repaired and the body analysis function restored.
Deutsch:
Reparatursatz für Withings Body+ Waage – Körperanalyse wiederherstellen
Dieser Reparatursatz ist für die Withings Body+ Waage, falls die Funktion zur Körperanalyse (Körperfett-, Muskel- und Wasseranteilmessung) nicht mehr korrekt arbeitet.
Eine häufige Ursache für diesen Fehler sind gebrochene oder beschädigte elektrische Kontakte innerhalb der Waage. Dadurch kann die Bioimpedanzmessung nicht mehr zuverlässig durchgeführt werden, obwohl die normale Gewichtsmessung weiterhin funktioniert.
Mit diesem Reparatursatz können die defekten Kontaktteile repariert und die Funktion der Körperanalyse wiederhergestellt werden.
Assembly:
Four M3x10 screws (ISO 4762) are required.
Es werden 4 Schrauben M3x10 (ISO 4762) benötigt.
Step 1
Carefully remove the cover
Break off the contacts so that only the contact at the solder joint remains
Leave the cables in the same position as the original setup.
Vorsichtig die Abdeckung entfernen
Kontakte abbrechen so dass nur noch der Kontakt mit der Lötstelle vorhanden ist
Die Kabel an der gleichen Stelle lassen wie es Original war


Step 2
Screw the retaining clips onto the bracket as shown. Tighten the retaining clips only lightly, the screws will be loosened again later.
Schraube Halteklammern so wie dargestellt, an Halterung anschrauben. Die Halteklammern nur leicht anschrauben, die Schrauben werden später wieder gelöst.


Step 3
Use tweezers to install the contacts, ensuring the solder joints face upwards
Once the mount is installed, loosen the screws until the retaining clips can be rotated 90 degrees (see image)
The retaining clips must be positioned underneath the glass plate (see image)
Then, tighten the screws until the mount is secure
Benutze eine Pinzette um die Kontakte zu Montieren, die Lötstellen sollen nach oben zeigen
Wenn Halterung eingebaut ist, die Schrauben so weit lösen bis sich die Halteklammern um 90 Grad drehen lassen, siehe Bild
Halteklammern müssen unter der Glasplatte sein, siehe Bild
Danach Schrauben festziehen bis die Halterung fest sitzt




Step 4
Fasten the contact holders with the screws so that the contacts are pressed against the glass plate
Install the cover cap
Schraube die Kontakt Halter mit den Schrauben fest, so das die Kontakte auf die Glasplatte gedrückt werden
Montiere die Abdeckkappe


Print orientation:
No support is required, everything is already incorporated into the design.
Es wird kein Support benötigt, es befindet sich alles schon in der Konstruktion.


Credits: