BTT (BIQU) Microprobe Mount for "The 100 v1.1" printer (v2.1)
Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.
Zapisane na tym urządzeniu.
Update to my previous v1.0 model. Rotated the probe 90 degrees which allowed it to be closer to the nozzle, NO SUPPORTS!
- Ocena
- 5 / 5
- Polubienia
- 10
- Pobrania
- 80
- Wydruki
- 2
- Wyświetlenia
- 1123
- Oceny
- 2
Aktualizacja u źródła:
Informacje o modelu
- Źródło
- Printables
- Kategoria
- Accessories
- Licencja
- Creative Commons — Attribution — Noncommercial — Share Alike
Updates to V2.1
- Changed the mounting holes for the microprobe from 2.8 to 3mm.
- Opened the X axis of the hole for the probe by 0.2mm to make it easier to insert the probe.
This is an update to my previous v1.0 model.
Since there wasn't a mount specifically for the BTT Microprobe, I created one. I look forward to other's input on improving this design. Hopefully someone way better than me with CAD will come out with a mount that gets closer to the nozzle.
I printed mine with these settings:
- Polymaker ASA (due to the close proximity to the nozzle) you can print this in PLA also.
- 270C
- 18 mm3/s flowrate
- 0.26mm layer heigh
- 0.6 width
- 30% gyroid infill
- 5 top 5 bottom 5 walls
- NO SUPPORTS NECESSARY!
I used 2 ea. M3x16 SCHS to mount the probe, and tightened the screws to adjust the probe close to the nozzle height. You should be able to go + or - 2mm from the nozzle. The spacer goes in between the mount and carriage.
Here's my Klipper config settings (I saved it as a seperate BTT_Microprobe.cfg file and placed [include BTT_Microprobe.cfg] in my printer.cfg). You'll have to keep it in your printer.cfg because the “probe” field is used during bed_mesh_calibrate and for probe_calibrate:
BLOCK 1:
# BTT_Microprobe.cfg
# Chinstrap777's BTT Microprobe v2 with "The 100 v1.1" printer and "BTT Microprobe Mount for 'The 100 v1.1' printer (v2.1)"
# Connected to "SERVOS" with the 3-wire connection and "PROBE" with the 2-wire connection on the BTT SKR Pico
# servos=gpio29 (yellow wire)
# probe=probe (white wire)
[output_pin probe_enable]
pin: gpio29
value: 0
[gcode_macro Probe_Deploy]
gcode:
SET_PIN PIN=probe_enable VALUE=1
[gcode_macro Probe_Stow]
gcode:
SET_PIN PIN=probe_enable VALUE=0
[safe_z_home]
home_xy_position: 75, 24 # Change coordinates to the center of your print bed
speed: 100
z_hop: 10 # Move up 10mm
z_hop_speed: 10
[gcode_macro PROBE_ACCURACY1]
gcode:
G90
G1 Z20
G1 X75 Y24 F3000
PROBE_ACCURACY
[gcode_macro PROBE_CALIBRATE1]
gcode:
G90
G0 Z20
G0 X75 Y24 F3000
G0 Z5
PROBE_CALIBRATE SPEED=1000
BLOCK 2:
And here's what I added to my PRINTER.CFG
[include BTT_Microprobe.cfg]
[probe] # this must be in the printer.cfg to ensure "SAVE CONFIG" works. The auto-generated values can only be sent to the printer.cfg and not other .cfg files
pin: ^!gpio22
deactivate_on_each_sample: False # true for probing without retracting probe after every contact (this is faster). Must also uncomment next line when changing this to FALSE
# probe_with_touch_mode: true # uncomment this line if changing "deactivate_on_each_sample: " to TRUE
# stow_on_each_sample: false # change this to TRUE and uncomment if setting "deactivate_on_each_sample: " to TRUE
x_offset: 0.0
y_offset: 51.0
#z_offset: 1.010 # this needs to be uncommented for the first calibration
speed: 4 # THIS IS THE Z SPEED WHILE PROBING
lift_speed: 30 # THIS IS THE Z SPEED AFTER PROBING
samples_tolerance: 0.01
activate_gcode:
Probe_Deploy
G4 P500
deactivate_gcode:
Probe_Stow
Tips:
- Ensure your probe is mounted perpendicular to your bed and straight with the toolhead.
- I used 2 ea. M3x 14mm socket head screws to mount the probe to the bracket, the original holes on the probe are M2.5. I would drill the holes on the probe itself out, but to just under 3mm to allow the screws to bite into the probe.
- Mount the probe so that the tip is 1-2mm above the tip of the nozzle. The easy way is to put your nozzle on the bed and then adjust the probe.
Installation
- Turn your printer off.
- Install the probe to the mount.
- 2 ea. M3x14 or M3x16 screws
- Install the mount (with the probe) to the toolhead.
- Use the original screws for 2 of them, and 2 ea. M3x16 for the mount through the spacer.
- Install the cable for the probe.
- Route the cable from the probe, through the cable sleeve/wrap for the toolhead, to the controller board. I had to extend mine by splicing it using 24 ga. silicone wire.
- Push the toolhead to the Y endstop.
- Turn your bed leveling knobs all the way tight, then back off 3-5 full rotations.
- Manually raise the bed by twisting the Z leadscrews the same direction, to the endstop. This ensures your bed mount is level with the gantry.
- Turn on your printer.
- Create BTT_Microprobe.cfg and paste the first block of settings into it.
- Update your PRINTER.CFG by adding the second block of settings.
- Be sure to uncomment the Z_OFFSET line before your first calibration. Afterwards, your offset will be saved in the autogenerated section at the bottom of PRINTER.CFG
- Run PROBE_CALIBRATE1 and hit SAVE_CONFIG. https://www.klipper3d.org/Probe_Calibrate.html?h=calibrating+probe+z+offset#calibrating-probe-z-offset
- Run BED_MESH_CALIBRATE1 at whatever bed temperature you're going to print with.
- ALL DONE! Happy printing!