1 / 3
CORE One + as a filament dryer — zdjęcie 1
1 / 3

CORE One + as a filament dryer

Zamów wydruk tego modelu

Obliczymy ostateczną cenę na podstawie wybranego pliku. Sprawdzisz ją i zaakceptujesz przed płatnością.

Zapisane na tym urządzeniu.

Use your CORE One as a dryer. Warning: ***Experimental****

Ocena
0 / 5
Polubienia
2
Pobrania
4
Wydruki
0
Wyświetlenia
144
Oceny
0

Aktualizacja u źródła:

Informacje o modelu

Źródło
Printables
Kategoria
Accessories
Licencja
Creative Commons — Attribution — Noncommercial — Share Alike

Turn your Prusa CORE One+ into a filament drying chamber

I’ve created a free set of nine experimental G-code files that let the heated bed and regulated chamber of the Prusa CORE One+ run as a filament dryer for 4, 6, or 8 hours.

Available files:

  • PLA: 4, 6, and 8 hours

  • PETG: 4, 6, and 8 hours

  • ABS: 4, 6, and 8 hours

Important compatibility warning

These files were developed and tested only on a standard Prusa CORE One+ without an MMU, using firmware 6.8.1.

They have not been tested with:

  • The original CORE One

  • CORE One+ Gen 2

  • CORE One L or L+

  • MMU3

  • INDX

  • Modified printers

  • Older or future firmware releases

  • Every possible spool, rack, filament, or hardware configuration

Prusa uses the shared COREONE compatibility identifier for the CORE One family. Therefore, the printer check cannot distinguish a CORE One+ from every other CORE One variant.

A file being accepted by the printer does not prove that it is safe for your particular printer configuration.

Use these files entirely at your own risk. Carefully supervise the first complete drying cycle.

How the files work

The printer performs the following sequence:

  1. Checks for the COREONE printer family.

  2. Keeps the nozzle heater switched off.

  3. Homes the printer with an empty heatbed.

  4. Lowers the bed to Z=200 mm.

  5. Pauses so you can install the rack and spool or spools.

  6. Opens the chamber vent once. (maybe)

  7. Starts bed heating and chamber-temperature regulation.

  8. Maintains the drying cycle for the selected time.

  9. Switches off the bed and nozzle heaters.

  10. Disables chamber regulation.

  11. Closes the vent. (Maybe)

  12. Disables the motors.

The files contain no filament/material compatibility check. Choosing a file with the correct material and safe temperature is your responsibility.

Temperatures

Material

Heatbed

Chamber target

PLA

60 °C

45 °C

PETG

70 °C

55 °C

ABS

100 °C

55 °C

The heatbed is the heat source. Its temperature is higher than the regulated chamber temperature.

Important safety rules

  • Start with a completely empty heatbed and chamber.

  • Do not put the rack or spools inside until the printer has opened the vent and lowered the bed.

  • Use a stable, heat-resistant metal rack with good airflow.

  • Never place spools directly on the heated sheet.

  • The combined height of rack and spools must stay below 20 cm and remain clear of the parked printhead, nozzle, gantry, door, walls and cables.

  • Multiple spools may be used only if they fit securely without reducing clearances or blocking airflow.

  • Check the maximum permitted temperature of every spool—not only the filament. Some plastic spools, cardboard spools, adhesives and labels cannot tolerate temperatures above 40 °C.

  • Remember that the heatbed temperature is higher than the chamber target.

  • Follow the usual fire-safety precautions for operating a heated 3D printer.

Instructions

  1. Empty the printer completely. Leave a print sheet.

  2. Select the required material and duration from the ZIP and start the G-code.

  3. The printer homes and opens the top vent while the chamber is empty.

  4. It lowers the bed to approximately Z=200 mm and displays a stationary prompt.

  5. Only now, place the rack and spool or spools on the bed. Check every clearance, close the door and press Continue.

  6. The drying cycle begins. No printhead movement occurs while the rack and spools are installed.

  7. When the timer finishes, all heating and chamber regulation stop. The printer waits for the bed to cool to 40 °C.

  8. At the next prompt, remove the rack and every spool. Make sure the chamber is empty, close the door and press Continue.

  9. The printhead closes the vent and then disables its motors.

Spool placement and maximum height

You can place more than one spool inside, provided that everything fits securely and air can circulate around each spool.

The maximum permitted total height above the bed is 20 cm. This includes:

  • The rack or spacer

  • Every spool

  • Any holder, axle, or support

Do not use the full 20 cm if movement, thermal expansion, an unstable stack, or spool dimensions could reduce the available clearance.

Never stack spools in a way that could fall, roll, deform, or contact the moving parts of the printer.

Never place spools directly on the heatbed

Always use a stable metal rack or spacer between the heated bed and the spools.

Direct contact with a 60–100 °C heatbed can:

  • Warp or soften spool sides

  • Damage cardboard spools

  • Soften glue

  • Cause spool halves to separate

  • Deform filament

  • Make adjacent filament strands stick together

The rack must be non-flammable, heat-resistant, stable, and able to support the spools throughout the complete cycle.

Check the temperature rating of every spool

Do not assume the spool can tolerate the drying temperature just because the filament can.

Some plastic, cardboard, glued, recycled, and refillable spools cannot safely tolerate temperatures above approximately 40 °C. Other spools may require a retaining screw or additional support when heated.

Before starting:

  • Check the spool manufacturer’s maximum temperature.

  • Check the filament manufacturer’s drying instructions.

  • Inspect the spool material, glue, fasteners, and construction.

  • Transfer the filament to a heat-resistant spool if necessary.

  • Use a lower temperature or a dedicated filament dryer when in doubt.

The displayed chamber temperature does not guarantee that every surface has exactly the same temperature. Areas close to the heatbed may be considerably hotter.

General safety warnings

  • This is an experimental use of the printer, not a certified filament dryer.

  • Do not leave the first cycle unattended.

  • Do not use damaged, deformed, or unknown spools.

  • Do not use flammable supports, packaging, foam, fabric, or improvised plastic racks.

  • Keep all air passages, fans, vents, electronics, and moving parts unobstructed.

  • Stop immediately if you notice unusual smells, deformation, slipping, noise, smoke, or error messages.

  • Keep the printer on a stable, non-flammable surface with normal fire-safety precautions.

  • Never exceed the printer, filament, spool, or rack manufacturer’s temperature limits.

These files are a convenient way to make better use of the CORE One+ chamber, especially when several spools need a long, controlled warm-air cycle—but safe setup and temperature selection remain entirely the user’s responsibility.

Why the files are supplied as a ZIP archive

The individual G-code files contain:

  • M870 O to open the chamber vent before chamber regulation starts

  • M870 C to close the vent after drying finishes

These commands are supported by the Prusa CORE One+ running firmware 6.8.1. However, the Printables G-code validator does not currently recognize M870 and may incorrectly report it as unsupported.

For this reason, the nine G-code files are provided together in a ZIP archive instead of being uploaded individually.

This packaging avoids the Printables validation error; it does not change or bypass any check performed by the printer itself.

Download and extract the ZIP before copying the required G-code file to the printer. Do not rename the ZIP to .gcode or send the ZIP directly to the printer.

Use these files only with the tested configuration: a standard Prusa CORE One+ without MMU, running firmware 6.8.1. Other printer variants, accessories, configurations, and firmware versions have not been fully tested.

Firmware 6.8.1 notes

  • The files now include the Input Shaper feature declaration expected by Firmware 6.8.1, eliminating the “Not sliced for Input Shaping” warning.

  • Automatic vent control is not a continuous chamber-temperature thermostat. It makes a vent decision from the selected filament profile during particular firmware events.

  • These jobs intentionally contain no filament declaration, so they explicitly open the vent before loading and close it only after everything has been removed.

  • M141 regulates the chamber cooling fans; it does not move the mechanical vent grille.

Official references: Buddy Firmware 6.8.1 and Prusa Buddy firmware-specific G-code commands.

Have a relaxing filament spa day—and please keep the sauna rules stricter than the filament’s. 🙂

PS:

The provided model is just a AI generated model fitting to this topic, because Printables requires me to upload a model.